6.6 MP40/50 buffer accumulator

6.6.1 5MPBAT.0000-00

6.6.1.1 General information

The accumulator in the Mobile Panel prevents the operator panel from restarting when the connection box or
cabinet is being changed. The Mobile Panel is therefore immediately ready for operation again after connecting.
The accumulator buffers for up to 15 minutes. If the Mobile Panel is connected to a connection box or
cabinet, then the accumulator is charged automatically. When fully charged, it will last for 4 cycles of 15 minutes.
When disconnected, the display switches off; keys, input devices and the
Mobile Panel is not connected within 15 minutes, the
described in more detail in section
Warning!
Charging or discharging the battery improperly
polarity or short circuit. It is only permitted to charge the accumulator in the Mobile Panel.
The following
safety
• Do not squeeze.
• Do not heat or burn.
• Do not short circuit.
• Do not disassemble.
• Do not submerge in liquid (the accumulator may rupture).
Information:
The accumulator is provided uncharged and must therefore be charged for at least 4 hours.
It should be noted that an accumulator discharges when not in use. If the accumulator is not used for
a long time, it may lose its charge completely.

6.6.1.2 Order data

Model number
Short description
Accessories
5MPBAT.0000-00
MP40/50 buffer accumulator

6.6.1.3 Technical data

Information:
The following specified characteristic data, features and limit values are only valid for these individual
components and may differ from those of the complete system. The data specified for the complete
system applies to the complete system in which this individual component is used, for example.
Model number
General information
Initial charging duration
Service life
Battery
Design
Certifications
CE
GOST-R
Mobile Panel 40/50 User's manual V1.80
"Installing the buffer accumulator" on page 128
guidelines apply to the Li-Ion accumulator:
Table 71: 5MPBAT.0000-00 - Order data
Table 72: 5MPBAT.0000-00 - Technical data
USB interface
control device
shuts itself off. Installing the accumulator is
can
cause a fire or explosion, e.g. due to reversed
5MPBAT.0000-00
At least 4 hours
500 charging cycles
Lithium ion
Yes
Yes
Accessories