Transport And Storage; Installation; Operation; Protection Against Contact With Electrical Parts - B&R Mobile Panel 40 User Manual

Table of Contents

Advertisement

All work such as installation, commissioning and servicing are only permitted to be carried out by qualified person-
nel. Qualified personnel are persons who are familiar with the transport, installation, assembly, commissioning and
operation of the product and have the appropriate qualifications for their job (e.g.
prevention regulations must be observed.
The
safety
guidelines, information about connection conditions (nameplate and documentation) and limit values
specified in the technical data must be read carefully before installation and commissioning and must be strictly
observed.

1.2.4 Transport and storage

During transport and storage, devices must be protected against undue stress (mechanical stress, temperature,
humidity, aggressive atmosphere).

1.2.5 Installation

• The devices are not ready for use and must be installed and wired according to the requirements of this
documentation in order to comply with
• Installation must be carried out according to the documentation using suitable equipment and tools.
• Devices are only permitted to be installed by qualified personnel when the power is switched off. The
cabinet must first be disconnected from the power supply and secured against being switched on again.
• General
safety
regulations and national accident prevention regulations must be observed.
• The electrical installation must be carried out in accordance with relevant regulations (e.g. wire cross sec-
tion, fuse protection, protective

1.2.6 Operation

1.2.6.1 Protection against contact with electrical parts

In order to operate programmable logic controllers, operating and monitoring devices and the uninterruptible power
supply, it is necessary for certain components to carry dangerous voltages over 42 VDC. Touching one of these
components
can
result in a life-threatening electric shock. There is a risk of death, serious injury or damage to
property.
Before switching on the programmable logic controllers, operating and monitoring devices and uninterruptible pow-
er supply, it must be ensured that the housing is properly connected to
connection must also be made if the operating and monitoring
connected for testing purposes or only operated for a short time!
Before switching on, live parts must be safely covered. All covers must be kept closed during operation.

1.2.6.2 Ambient conditions - Dust, moisture, aggressive gases

The use of operating and monitoring devices (e.g. industrial PCs,
ruptible power supplies in dusty environments must be avoided. This
the functionality of the device, especially in systems with active cooling (fans), which may no longer guarantee
sufficient cooling.
The presence of aggressive gases in the environment
temperature and relative humidity, aggressive gases – for example with sulfur, nitrogen and chlorine components
– trigger chemical processes that
surfaces and cable ends in existing installations are indicators of aggressive gases.
When operated in rooms with dust and condensation that
devices such as
Automation
moisture when installed correctly (e.g. cutout installation). The back of all devices must be protected against the
ingress of dust and moisture, however, or the dust deposits must be removed at suitable intervals.

1.2.6.3 Programs, viruses and malicious programs

Any data exchange or installation of
drive, etc.) or via networks or the
avert these dangers and to take appropriate measures such as virus protection programs, firewalls, etc. to protect
against them and to use only
Mobile Panel 40/50 User's manual V1.80
EMC
limit values.
ground
connection).
can
very quickly impair or damage electronic components. Blackened copper
Panels or
Power
Panels are protected on the front against the ingress of dust and
software
using data storage media (e.g.
Internet
poses a potential threat to the system. It is the user's own responsibility to
software
from trustworthy sources.
ground
device
and uninterruptible power supply are only
Power
Panels, Mobile Panels, etc.) and uninter-
can
otherwise lead to dust deposits that affect
can
also result in malfunctions. In combination with high
can
endanger functionality, operating and monitoring
floppy
General information
IEC
60364). National accident
potential (PE rail). The
disk, CD-ROM,
USB
control
ground
flash
11