Information:
The following specified characteristic data, features and limit values are only valid for these individual
components and may differ from those of the complete system. The data specified for the complete
system applies to the complete system in which this individual component is used, for example.
Properties
Output type
Switchable nominal voltage
Switchable
nominal current
Maximum interrupting current
Circuit 1
Circuit 2
Maximum inductive load
Circuit 1
Circuit 2
Reverse polarity protection
Circuit 1
Circuit 2
Short circuit and overload protection
Circuit 1
Circuit 2
Switching cycles
Switch
position 2
Switch
position 3
Actuating force
From
switch
position 1 to 2
From
switch
position 2 to 3
Specifications for
EN ISO
13849-1:2008
Enable
Category
Performance level
Proof test interval
MTTF
symmetrized per D.2 of
d
PFH
d
Panic
Category
Performance level
Proof test interval
MTTF
symmetrized per D.2 of
d
PFH
d
1)
The monitoring
device
is not accounted for in the MTTF
130
EN ISO
13849-1
EN ISO
13849-1
specifications. See also TBD.
d
Enable
Solid-state output
(voltage tolerance 19.2 VDC to 30 VDC per
500 mA (max.)
145 mJ / 1.16 H @ 24 VDC, 500 mA (comparable to DC13 per
145 mJ / 1.16 H @ 24 VDC, 500 mA (comparable to DC13 per
Yes (integrated in output FET)
Yes (by protective circuit)
Typically 5 N
Typically 20 N
1.35x 10
switch
24 VDC
EN
61131-2)
1.5 A
0.8 A
EN
60947-5-1)
EN
60947-5-1)
Yes
Yes
10
5
5x 10
4
3
d
20 years
78 years
1.57x 10
-7
3
d
20 years
88 years
-7