Connection Examples; Connection Example For Stop Button - B&R Mobile Panel 40 User Manual

Table of Contents

Advertisement

Commissioning

3.4 Connection examples

Information:
The monitoring
device
enabling
safety
function.
A suitable monitoring

3.4.1 Connection example for stop button

Connection example with monitoring
Control cabinet
1) Contacts K1 and K2 must be positively driven!
70
and subsequent components must also be included when calculating the entire
device
must be used to detect short and cross faults in the connecting cable.
device
for
safety
Mobile Panel 40/50
(stop button wired with 2 circuits)
+ 24 VDC
Safety relay
Min. category 3 PL d
per EN ISO13849-1:2008.
Figure 45: Connection example for stop button
circuits up to category 3 PL d per
Stop button
Attachment cables
5CAMPH.0xxx-30
Industrial connector
and
connection housing
Control cabinet cables
5CAMPC.0020-1x
Auxiliary output
e.g. PLC error message output
EN ISO
13849-1:2008.
Enable
for the
hazardous
movement
Mobile Panel 40/50 User's manual V1.80

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents