How To Restore Factory Default; Error Code List - Furuno FSV-75 Installation Manual

Half-circle color scanning sonar
Hide thumbs Also See for FSV-75:
Table of Contents

Advertisement

3.13

How to Restore Factory Default

Do as follows to restore factory default settings:
1. With the MENU/ESC key pressed and held, press 1/F1, 3/F3, 5/F5 in order.
The system menu items appear on the main menu. Repeat the above procedure
to hide the system menu items.
2. Press the MENU/ESC key to open the menu.
3. Select [9 Installation Setting].
A confirmation message appears.
4. Select [OK].
5. Select [System Setting].
6. Select [System All Default].
The following confirmation message appears.
7. Select [Yes] to restore factory default settings.
The following confirmation message appears.
8. Restart the system to apply the setting.
3.14

Error Code List

The error code list shows the possible errors for this equipment.
Do as follows to open the error code list.
1. With the MENU/ESC key pressed and held, press 1/F1, 3/F3, 5/F5 in order.
The system menu items appear on the main menu. Repeat the above procedure
to hide the system menu items.
2. Press the MENU/ESC key to open the menu.
3. Select [9 Installation Setting].
A confirmation message appears.
4. Select [OK].
5. Select [System/Maintenance].
System All Default
All settings will be initialized. Are you sure? (Restart is required)
Press the power key to restart.
Menu
Installation Setting
System/Maintenance
Error Code List
Show Error Log
Show Operations Log
Output Error Log
Output Operation Log
Motor Operating Time INIT
Set the Year/Month of Oil Change
Yes
Cancel
Confirm
Quit
Not used at installation.
These menu items are for
developer/technicians.
3. ADJUSTMENTS
3-17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fsv-75-3d

Table of Contents