Half-circle color scanning sonar
Hide thumbs Also See for FSV-75:
Table of Contents

Advertisement

2. WIRING
Cable from matching box (10CA10110 cable)
The labels on each 10CA10110 cable from the
matching box indicate where to connect the cable.
For example, the cable labeled "TRANSCEIVER
UNIT 2" is connected to the TRX2 board (CN-
TR602).
Notice before turning the power on
Before turning the power on, switch the input voltage toggles (S603, S604, S605) ac-
cording to the input voltage. This prevents the incorrect voltage being input to the
transceiver unit. For details about the input voltage toggle switch, see section 2.3.3.
2.3.2
Cable fabrication
10S2380 cable
Fabricate the cable referring to section 2.1.3.
LAN cable
Fabricate the cable referring to section 2.1.3.
DPYCY-2.5 cable
Fabricate the cable as shown in the following figure.
Outer vinyl sheath
Vinyl tape
2-12
230
230
170
170
Armor Inner vinyl sheath
Vinyl tape
35 35
Clamp here.
The number on the label must match
the number of the TRX board.
Cores
Attach crimp-on
lugs (FV2-4,
supplied locally).