2.3.3
Input voltage
The transceiver unit is shipped from the factory with the input voltage set for 230 VAC.
If your vessel uses a different voltage, change the toggle switches referring to the fol-
lowing table.
Input voltage
230V (default)
2.3.4
Removing and inserting a printed circuit board
To remove a printed circuit board in the transceiver unit, unfasten the securing screw
and unlock the lock lever.
To insert a printed circuit board, insert the board until the lock lever catches on the up-
per and lower projection, then push the lock lever inwards (see the following figure).
After the board is locked in place with the lock lever, confirm that the inside end of the
securing screw is firmly against the chassis, then fasten the securing screw. If the
screw is not firmly against the chassis, the board may be inserted incorrectly. Remove
and re-insert the board.
S605
100V
110V
115V
220V
Unlock
Unlock
S604
L
L
L
L
L
H
H
L
H
H
Securing screw:
One screw for each PCB
Lock levers at upper
and lower side
Insert the printed circuit
board until the lock lever
catches this projection, then
push the lock lever inwards.
2. WIRING
S603
L
H
H
H
H
2-13