2. WIRING
Notes for network construction
• The transceiver unit must be directly connected to the processor unit. Do not use a
network hub for this Ethernet connection.
• When you need 10 m or more cable for the control unit and monitor unit, prepare a
commercial adapter.
• For configurations with two monitor units, make sure the resolution is the same for
both monitors. Both monitors must also be landscape oriented. The FSV-75 cannot
display images correctly if the monitors do not meet these requirements.
• Do not cut the HDMI cable between the monitor unit and processor unit.
• If the cable between the monitor unit and processor unit is disconnected and recon-
nected while the system is powered, the FSV-75 may display images incorrectly.
Restart the system if this occurs.
• For configuration with either the MU-190 or MU-190-HD monitor units, monitor bril-
liance can be adjusted from the control unit. To use this feature, connect a USB ca-
ble between the monitor unit and the processor unit. The USB cable must be
connected directly between the units; do not use a USB hub.
• For configurations with dual monitors, connect the main monitor to the HDMI1 port
and the sub monitor to the HDMI2 port.
2-2