Furuno FSV-75 Installation Manual page 72

Half-circle color scanning sonar
Hide thumbs Also See for FSV-75:
Table of Contents

Advertisement

2. WIRING
Pin
No.
1
GND
2
24V
3
CONTROL_GND
4
CONTROL_LIGHT Contact output for lighting signal
5
CONTROL_BUZZ
6
SHIELD
The following example uses the recommended signal light (PEW-24AB, manufactur-
er: PATLITE).
Note: For signal lights other than the recommended product, refer to the signal light's
wiring diagram before connecting the light to the FSV-75.
Recommended signal litht
· Model: PEW-24AB
· Manufacturer: PATLITE
Control box
SHIELD
CONTROL_BUZZ
CONTROL_LIGHT
CONTROL_GND
*
: If the alarm sound is not required when lowering/raising the transducer, set the alarm signal as
open.
2.4.5
Contact output
TB5-1 and TB5-2 in the control box can output a contact signal. Contact specifications
of this equipment are as follows:
Contact specifications
Contact rating
Note: To use the contact signal from TB5, twist the contact output wires with the hull
unit limit switch wires, then connect the wires to TB5-1 and TB5-2.
2-22
Signal
GND
Power output (24 VDC)
GND for TB3-4 and TB3-5
Contact output for buzzer/flashing
signal
Open
TB3
*
Alarm
6
Flash
5
Light
4
Common
3
Power
24V
2
Power
GND
1
• When the transducer is retracted: Open
• Others: Closed
• 125 VAC, 3 A or less
• 30 VDC, 1.5 A or less
Control
TB5
box
1
2
3
14
Description
Signal light
Hull unit status
Raising/Lowering
Projected
Retructed
Contact output
Signal wires from hull
unit limit switches
Remarks
-
24 VDC, steady state
current 1.0 A or less
-
60 VDC, 0.5 A or less
60 VDC, 0.5 A or less
-
Signal light status
Flashes and alarm sounds
ON
OFF

Advertisement