APPENDIX 2 INSTALLATION CHECK
LIST
After completing the installation, perform the following checks:
Hardware installation check
Sonar oil
O-ring in the retraction
tank flange
Tank guide position at
transducer full protrusion
Bow mark direction of the
transducer
Soundome assembly op-
eration check
Input voltage toggle
switch on the transceiver
unit
Vibration and sound
while raising/lowering the
transducer
Software setting check
Language setting
Year/Month of oil change Register the year and month of the sonar oil
Transducer position reg-
istration
Turn the transmission on Change the transmission status from [OFF]
Heading Correction
Direction offset of the
motion sensor
Stroke setting
External data setting
System time setting
Save ship's original set-
ting
AP-2
Check point
The dome is filled with the sonar oil.
O-ring, gasket* and insulation packing* are
attached to the retraction tank flange.
*: Attached only when the attachment kit or
attachment flange is used.
Lower the transducer until fully protruded,
then confirm that the rollers on the tank guide
are not projected from the retraction tank.
Tank guide must be positioned 30 mm inside
from the bottom of the retraction tank.
Confirm that the bow mark on the transducer
faces the bow direction.
Check the LEDs in the control box to perform
the soundome assembly operation check.
Input voltage toggle switches on the trans-
ceiver unit are changed correctly, depending
on the input voltage.
Confirm that abnormal vibration or noise is
not generated from the hull unit while raising/
lowering the transducer.
The language in which the menus and indi-
cations is changed as necessary.
change.
The transducer position registration is com-
pleted.
to [ON].
Adjust the heading so an echo which is dead
ahead appears dead ahead on the display.
Offset the direction difference between the
[Reference Direction] mark on the motion
sensor and bow direction.
Select 800 mm or 1100 mm according to the
stroke (length) of your hull unit.
Set the baud rate for the NMEA2000 port and
select the input format for external data.
Set the system time and time zone.
Save all menu settings in the internal memo-
ry as necessary.
Reference
Result
section 1.9
section 1.2.5/
section 1.10.1/
section 1.10.2
-
section 1.2.9
section 1.2.10
section 2.3.3
-
section 3.2
section 3.16
section 3.3
section 3.4
section 3.5