1. MOUNTING
Disconnection/short circuit check
When one or more of the following errors occur, perform a disconnection/short circuit
check for the resolver or motor.
Occurred error
9 Motor Test Error (Tilt)
10 Motor Driver Error (Rotate)
11 Motor Driver Error (Tilt)
16 Motor Test Error (Rotate)
14 Resolver Test Error (Rotate) Perform a disconnection/short circuit check for the re-
15 Resolver Test Error (Tilt)
• Disconnection/short circuit check for the motor
Remove the terminal block 734-209-FUR from the TB1 (HFLT board) in the control
box, then measure resistance using a multimeter.
Terminal block 734-209-FUR
1 2 3 4 5 6 7 8 9
Coil
Coil
Rotation motor
• Disconnection/short circuit check for the resolver
Remove the terminal block 733-106-FUR and 733-110-FUR from the TB8 and TB10
in the control box, then measure resistance using a multimeter.
Terminal block 733-106-FUR
1 2 3 4 5 6
Excitation
coil
Rotation resolver
Terminal block 733-110-FUR
1 2 3 4 5 6 7 8 9 10
Excitation
Output coil
coil
Output coil
Tilt resolver
1-20
Measured point
1-2, 3-4
6-7, 8-9
1-3
6-8
Coil
Coil
Between ground
Tilt motor
point (hull unit
chassis) and pins 1
thru 4, 6 thru 9
Measured point
1-2
3-5, 4-6
3-4
Between ground
Output coil
point (hull unit
Output coil
chassis) and pins 1
thru 6
Measured point
1-2
3-5, 4-6
3-4
Between ground
point (hull unit
chassis) and pins 1
thru 6
Check point
Perform a disconnection/short circuit check for the
motor.
solver.
Correct value
If the measured value is not correct value...
10
30 Ω
Rotation motor or motor cable error
Tilt motor or motor cable error
10
30 Ω
Insulation failure in the rotation motor or motor
cable.
Insulation failure in the tilt motor or motor
cable.
Insulation failure in the motor or motor cable.
Correct value
If the measured value is not correct value...
Rotation resolver or resolver cable error
50 to 70Ω
100 to 130Ω
When the extension box is used:
Insulation failure in the extension box
Correct value
If the measured value is not correct value...
50 to 70 Ω
Tilt resolver or resolver cable error
100 to 130 Ω
When the extension box is used:
Insulation failure in the extension box