Warnings And Safety - Riello Start Aqua Condens 25/60 BIS Installer And User Manual

Hide thumbs Also See for Start Aqua Condens 25/60 BIS:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 24
Start Aqua Condens 25/60 BIS
ENGLISH
EN
INSTALLATION MANUAL
1 -

WARNINGS AND SAFETY

9
After removing the packaging, check the integrity and
completeness of the supply and, otherwise, contact the Riello
Agency that sold the boiler.
9
The Start Aqua Condens 25/60 BIS boiler must be installed
by a qualified company in accordance with the regulations
in force, at the end of the installation process, must issue
the owner with a declaration of conformity certifying that the
installation has been performed according to the best working
practices and in observance of applicable legislation and of
the indications provided by Riello in the present instructions
booklet.
9
The installer must instruct the user about the operation of the
appliance and about essential safety regulations.
9
When carrying out routine maintenance, it is always
recommended to check the consumption level of the sacrificial
anode.
9
The boiler must be used for the purpose for which it was
expressly built. The manufacturer accepts no liability within or
without the contract for any damage caused to people, animals
and property due to installation, adjustment and maintenance
errors or to improper use.
9
In the event of a water leakage, shut off the water supply and
promptly contact the Technical Assistance Centre or other
professionally qualified personnel.
9
Not using the boiler for an extended period of time involves
the execution of at least the following operations:
- turn the main appliance switch and the main system switch
to "off"
- close the fuel and water taps of the heating system
- drain the heating and domestic hot water circuits if there is
a risk of freezing.
9
The boiler maintenance must be carried out at least once a
year.
9
This booklet and that of the User are an integral part of the
appliance and therefore should be carefully preserved and
should always accompany the boiler even when it is sold to
another owner or user or when transferred to another system.
In case of loss or damage, please contact your local Technical
Assistance Centre for a new copy.
9
The boiler is constructed so as to protect both the user and
the installer from any accidents. After each intervention on the
product, pay special attention to the electrical connections,
especially the stripped parts of the wires, which must not
protrude from the terminal board in any way.
9
At the end of its life, the product should be not be disposed of
as solid urban waste, but rather it should be handed over to a
differentiated waste collection centre.
9
Dispose of all the packaging materials in the suitable
containers at the corresponding collection centres.
9
When disposing of waste, be careful not to harm human
health or employ procedures or methods which may damage
the environment.
Remember that the use of products requiring fuels, electricity and
water necessitates the respect of certain basic safety rules such as:
0
it is forbidden for children and unassisted unskilled people to
use the boiler;
24
0
it is forbidden to activate electric devices or appliances such
as switches, household appliances and so on if you notice a
smell of fuel or unburnt fuel;
0
in this case:
- ventilate the room by opening the doors and windows
- close the fuel shut-off device
- promptly
call
the
professionally qualified personnel;
0
it is forbidden to touch the boiler while barefoot or if parts of
your body are wet;
0
it is forbidden to carry out any cleaning operations before
disconnecting the boiler from the electricity supply; to do this,
turn the main system switch to "OFF";
0
it is forbidden to modify safety and adjustment devices without
the boiler manufacturer's permission and relative instructions;
0
it is forbidden to pull, detach or twist the electric cables that
emerge from the boiler, even if the boiler itself is disconnected
from the mains supply;
0
it is forbidden to plug or reduce the size of any openings used
for airing the installation area;
0
it is forbidden to leave flammable containers and substances
in the room where the boiler is installed;
0
it is forbidden to disperse and leave packaging material within
children's reach as it may be a potential source of hazard;
0
it is forbidden to obstruct the condensate outlet.
2 -
DESCRIPTION
Start Aqua Condens 25/60 BIS is a wall-hung condensing boiler,
with premix burner and low emission of pollutants for heating and
for the production of DHW use and has a 60 litre steel storage tank.
This is an electronically controlled boilers with automatic ignition,
ionisation flame check and with proportional control system of the
gas and air flows, both in heating and DHW.
It uses an aluminium alloy boiler body, has a sealed combustion
chamber and, based on the gas discharge accessory used, is
classified in categories B23P, B53P, C13-C13x, C33-C33x, C43-
C43x, C53-C53x, C83-C83xC93C93x. The switching of the heating
and DHW modes is performed via a three-way electric valve which
set on DHW when in the rest position. To guarantee the correct
water output in the exchanger, the boiler is equipped with an
automatic by-pass.
The Start Aqua Condens 25/60 BIS boiler is also equipped with:
- Range Rated - this means the boiler is equipped with a device
that adapts it to the heat requirements of the system, so the
boiler output can be adjusted according to the energy needs of
the building.
- Circulator anti-blocking.
- First-level antifreeze (suitable for indoor installations).
- 10 litre expansion tank.
- 2 litre DHW expansion tank.
- Digital display indicating the operating temperature and alarm
codes.
- Pre-mix low emissions burner.
- Continuous electronic flame modulation for domestic hot water
and heating.
- Premix combustion system which ensures a constant air-gas
ratio.
- Anti-legionella: Legionella is a disease that can be contracted
by inhaling small droplets of water (aerosols) which contain the
Legionella bacteria (bacteria occurs naturally in lakes and rivers
all over the world). The decimation of the bacterium is obtained
by taking the stored water to a temperature over 50/55° C.
Technical Assistance
Centre
or

Advertisement

Table of Contents
loading

Table of Contents