Warnings And Safety; Installation - Riello RESIDENCE KIS Installer And User Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 4
RESIDENCE
ENGLISH
EN
1

WARNINGS AND SAFETY

b
The boilers manufactured in our factories are checked even in the smallest details in
order to protect users and installers against possible injury. After working on the product,
qualified personnel must check the electrical wiring, in particular the stripped part of
leads, which must not protrude from the terminal board and avoiding possible contact
with live parts of the leads themselves.
b
This installer and user manual constitutes an integral part of the product: make sure they
are always kept with the appliance, even if it is transferred to another owner or user, or
moved to another heating system. In the event of loss or damage, please contact your
local Technical Assistance Centre for a new copy.
b
The boiler must only be installed and serviced by qualified personnel, in accordance with
current regulations.
b
The installer must instruct the user about the operation of the appliance and about es-
sential safety regulations.
b
This boiler must only be used for the application it was designed for. The manufacturer
accepts no liability within or without the contract for any damage caused to people, animals
and property due to installation, adjustment and maintenance errors or to improper use.
b
This appliance should not be operated by children younger than 8 years, people with
reduced physical, sensory or mental capacities, or inexperienced people who are not
familiar with the product, unless they are given close supervision or instructions on how
to use it safely and are made aware by a responsible person of the dangers its use might
entail. Children must not play with the appliance. It is the user's responsibility to clean
and maintain the appliance. Children should never clean or maintain it unless they are
given supervision.
b
After removing the packaging, make sure the content is in good condition and complete.
Otherwise, contact the dealer from whom you purchased the appliance.
b
The safety valve outlet must be connected to a suitable collection and venting system.
The manufacturer declines all liability for any damage caused due to any intervention
carried out in the safety valve.
b
The seal of the condensate drainage connection line must be secure, and the line must
be fully protected against the risk of freezing (e.g. by insulating it).
b
Check that the rainwater drainage channel of the flue gas exhaust coupling and the
relative connecting pipe are free of obstructions.
b
Dispose of all the packaging materials in the suitable containers at the corresponding
collection centres.
b
Dispose of waste by being careful not to harm human health and without employing
procedures or methods which may damage the environment.
b
During installation, inform the user that:
- in the event of water leaks, the water supply must be shut off and the Technical Assi-
stance Centre contacted immediately
- periodically check that the operating pressure of the hydraulic system is comprised
between 1 and 1.5 bar.
b
If the boiler is not used for a long period of time, it is recommended to perform the
following operations:
- turn the main switch of the appliance to "OFF"
- set the boiler status to OFF (
- close the fuel and water taps of the heating and domestic hot water system
- empty the heating and domestic hot water circuits if there is the risk of freezing
b
Boiler maintenance must be carried out at least once a year; this should be booked in
advance with the Technical Assistance Centre to ensure the necessary safety standards.
b
For the assembly, programming and commissioning of the boiler when used in hybrid
systems with a heat pump, storage cylinder and solar heating circuit refer to the system
manual.
At the end of its life, the product should be not be disposed of as solid urban waste, but
rather it should be handed over to a differentiated waste collection centre.
For safety reasons, please remember that:
a
It is forbidden to activate electric devices or appliances such as switches, household
appliances and so on if you notice a smell of fuel or unburnt fuel. In this case:
- ventilate the room by opening the doors and windows
- close the fuel shut-off device;
- ask the Technical Assistance Service or professionally qualified personnel to intervene
promptly.
a
It is forbidden to touch the appliance while barefoot or if parts of your body are wet.
a
Any technical or cleaning operation is forbidden before disconnecting the appliance from
the main power supply by turning the system's main switch to "OFF" by setting the boiler
to "OFF" (
).
4
)
a
Do not modify the safety or adjustment devices without the manufacturer's authorisation
and precise instructions.
a
It is prohibited to pull, detach or twist the electrical cables coming from the appliance
even if it is disconnected from the mains power supply.
a
Avoid blocking or reducing the size of the air vent openings in the installation room, do
not leave inflammable containers and substances in the room where the appliance is
installed.
a
Do not leave flammable containers and substances in the room where the device is
installed.
a
It is forbidden to disperse the packaging material in the environment and leave it within
children's reach as it may be a potential source of danger. It must be disposed in accor-
dance with the present law.
a
It is forbidden to obstruct the condensate drain outlet. The condensate drain pipe should
be facing the discharge pipe, preventing the formation of further drain pipes.
a
Never carry out any work on the gas valve.
a
Only for the user: Do not access the inside of the boiler. Any work on the boiler should
be carried out by the Technical Assistance Centre or by professionally qualified personnel.
INSTALLATION MANUAL
2
DESCRIPTION
The Residence KIS boilers have a new ACC combustion control system (active combustion
control).
This new control system, developed by Riello, in all circumstances provides functionality, effi-
ciency and low emissions.
The ACC system uses an ionisation sensor immersed in the burner flame, whose information
allows the control board to operate the gas valve that regulates the fuel.
This sophisticated control system provides for the auto adjustment of the combustion, thereby
eliminating the need for an initial calibration
The ACC system can adapt the boiler to operate with different gas compositions, different pipe
lengths and various altitudes (within the design limits).
The ACC system can also perform an auto-diagnostic operation that locks out the burner before
the permitted upper emission limit is exceeded.
Residence KIS is a type C condensing wall-hung boiler to be used for heating and the produc-
tion of domestic hot water.
Depending on the fume discharge accessory used, it is classified in categories B23P; B53P;
C(10)*; C13,C13x; C33,C33x; C43,C43x; C53,C53x; C83,C83x; C93,C93x.
* Currently not available on model 40kW.
In configuration B23P (when installed indoors), the appliance cannot be installed in bedrooms,
bathrooms, showers or where there are open fireplaces without a proper air flow. The room whe-
re the boiler is installed must have proper ventilation. Detailed requirements for the installation of
the flue, the gas piping and for ventilating the room, can be found in UNI 7129-7131.
In configuration C, the appliance can be installed in any type of room and there are no limitations
due to ventilation conditions or room volume.
3

INSTALLATION

3.1
Cleaning the system and characteristics of the water
In the case of a new installation or replacement of the boiler, it is necessary to clean the heating
system. To ensure the device works well, top up the additives and/or chemical treatments (e.g.
anti-freeze liquids, filming agents, etc.) and check the parameters in the table are within the
values indicated.
PARAMETERS
UM
HEATING CIRCUIT WATER
pH value
Hardness
°F
Appearance
Fe
mg/kg
Cu
mg/kg
3.2
Dimensions and weights (fig. 5)
25 KIS
L
420
P
275
H
740
H1(*)
822
Net Weight
35
(*) Comprehensive of SRD device
3.3
Handling (Fig. 6)
After unpacking, handling of the boiler is done manually using the support frame.
FILLING WATER
7–8
-
-
clear
0.5
0.1
Residence KIS
30 KIS
35 KIS
40 KIS
420
420
420
350
350
350
740
740
740
822
822
822
37
37
40
-
< 15
-
-
mm
mm
mm
mm
kg