1 - Warnings and safety

1.1 - General warnings
9 To guarantee the correct water output in the exchanger, the boil-
ers are equipped with an automatic by-pass.
9 After removing the packaging, check the integrity and complete-
ness of the supply and, otherwise, contact the Agency that sold
the boiler.
9 The installation of the START CONDENS Kis boiler must be per-
formed by a qualified company in accordance with current regu-
lations that will issue the owner with the installation declaration
of conformity on completion of the work, in compliance with the
applicable Standards and the instructions supplied by r in
the present instruction booklet.
9 The installer must instruct the user about the operation of the
appliance and about essential safety regulations.
9 This appliance should not be operated by children younger than
8 years, people with reduced physical, sensory or mental capac-
ities, or inexperienced people who are not familiar with the prod-
uct, unless they are given close supervision or instructions on
how to use it safely and are made aware by a responsible person
of the dangers its use might entail. Children must not play with
the appliance. It is the user's responsibility to clean and maintain
the appliance. Children should never clean or maintain it unless
they are given supervision.
9 The boiler must be destined for the intended use for which it
was purposely designed. The manufacturer accepts no liability
within or without the contract for any damage caused to people,
animals and property due to installation, adjustment and mainte-
nance errors or to improper use.
9 In case of water leakage, close the water supply and immedi-
ately contact the Technical Assistance Service or professionally
qualified personnel.
9 From time to time, check the icon does not light up on the dis-
play; this symbol indicates an incorrect charge pressure. Other-
wise, refer to paragraph "Smart system filling".
9 Not using the boiler for an extended period of time involves the
execution of at least the following operations:
• turn the main appliance switch and the main system switch
to "off"
• Close the fuel and water taps of the heating system
• Drain the heating and domestic hot water circuits if there is a
risk of freezing.
9 The boiler maintenance must be carried out at least once a year.
9 This booklet and that of the User are an integral part of the
appliance and therefore should be carefully preserved and
should always accompany the boiler even when it is sold to
another owner or user or when transferred to another system.
In case of loss or damage, please contact your local Technical
Assistance Service for a new copy.
9 The boilers are constructed so as to protect both the user and
the installer from any accidents. After each intervention on the
product, pay special attention to the electrical connections,
especially the stripped parts of the wires, which must not
protrude from the terminal board in any way.
9 Dispose of all the packaging materials in the suitable containers
at the corresponding collection centres.
9 Dispose of waste by being careful not to harm human health and
without employing procedures or methods which may damage
the environment.
9 At the end of its life, the product should be not be disposed of
as solid urban waste, but rather it should be handed over to a
differentiated waste collection centre.
9 Regularly check that the discharge manifold is not blocked by
solid residues that might prevent the outflow of condensate water.
9 Sealing of the condensate drainage connection line must be
guaranteed.
9 The intervention of the safety devices indicates a boiler
malfunction, therefore immediately contact the Technical
Assistance Service.
9 Replacement of safety devices must be performed by the
Technical Assistance Service, by exclusively using original
manufacturer components and referring to the spare parts list
accompanying the boiler.
1.2 - Basic safety rules
Remember that the use of products requiring fuels, electricity and
water necessitates the respect of certain basic safety rules such as:
0 It is forbidden to activate electric devices or appliances such as
switches, household appliances and so on if you notice a smell
of fuel or unburnt fuel.
0 In this case:
• Ventilate the room by opening the doors and windows
• Close the fuel shut-off device
• Request the prompt intervention of the Technical Assistance
Service or professionally qualified personnel.
0 It is forbidden to touch the boiler while barefoot or if parts of your
body are wet.
0 It is forbidden to carry out any cleaning operations before discon-
necting the boiler from the electricity supply; to do this, turn the
main system switch to "OFF".
0 It is forbidden to modify safety and adjustment devices without
the boiler manufacturer's permission and relative instructions.
0 It is forbidden to pull, detach or twist the electric cables that
emerge from the boiler, even if the boiler itself is disconnected
from the mains supply.
0 It is forbidden to plug or reduce the size of any openings used for
airing the installation area.
0 Do not access the inside of the boiler. Any work on the boiler
should be carried out by the Technical Assistance Centre or by
professionally qualified personnel.
0 It is forbidden to leave flammable containers and substances in
the room where the boiler is installed.
0 It is forbidden to disperse and leave packaging material within
children's reach as it may be a potential source of hazard.
0 It is forbidden to obstruct the condensate outlet.
0 The boiler must not be put in service, even temporarily, with
non-operating or tampered safety devices.
1.3 - BOILER description
START CONDENS Kis are a wall-hung condensing boiler with pre-
mix burner and low emission of pollutants for heating and for DHW,
equipped with a stainless steel plate heat exchanger. These are
electronically controlled boilers with automatic ignition, ionisation
flame check and with proportional control system of the gas and air
flows, both in heating and DHW.

2 - Installation

2.1 - Receiving the product
START CONDENS Kis boilers are supplied in single package pro-
tected by cardboard packaging.
The boiler is supplied as standard with the following material:
• Installer's and user's instructions booklet.
• Bar code labels.
• Flue gas analysis adaptor plug.
• Supporting cross-member.
9 The instruction booklet is an integral part of the boiler and should
therefore be read and kept in a safe place.
2.2 - Installation room
In configuration C, the appliance can be installed in any type of room
and there are no limitations due to ventilation conditions or room
volume since START CONDENS Kis are boilers with an "airtight"
combustion circuit in relation to the installation environment.
In configuration B23P, B53P the appliance cannot be installed in
bedrooms, bathrooms, showers or where there are open fireplaces
without a proper air flow. The room where the boiler is installed must
have proper ventilation.
9 Consider the clearances necessary to access safety and adjust-
ment devices and to perform maintenance operations.
9 Check that the electric protection level of the appliance is adapt-
ed to the installation room characteristics.
9 In case the boilers are supplied with fuel gas of a specific weight
greater than that of the air, the electric parts will have to be
placed at a level above the ground greater than 500 mm.
21