Before installation

Intended Use

The cleaning device is used exclusively to mechanically clean Fronius robot welding torch-
es in automatic mode within the limits of technical data, especially to clean the gas nozzle
and gas nozzle internal space. Any other use does not constitute proper use. The manu-
facturer shall not be liable for any damage resulting from such improper use.
Proper use also means
-
-
-
Operating Per-
NOTE!
sonnel, Mainte-
nance Personnel
In all situations, the device must only ever be operated by one person.
It must also be ensured that there are no other people in the device's operating area while
it is in operation.
NOTE!
In all situations, the device must only ever be maintained by one person.
It must also be ensured that there are no other people in the device's operating area while
work on it is ongoing.
Setup Regula-
The cleaning device has been tested according to protection class IP 21. This means:
tions
-
-
The device should not be set up and operated outdoors. The installed electrical compo-
nents should be protected against direct exposure to moisture.
Specifications for
To ensure the proper functioning of the cleaning device, fulfill the following specifications
the Compressed
for the compressed air supply:
Air Supply
-
-
Measures to en-
If untrained operating personnel have access to the device, the compressed air supply to
sure safe opera-
the device must be disconnected for the duration of this access in accordance with "Per-
tion of the device
formance Level d" of ISO 13849-1.
when operating
personnel are un-
We recommend FESTO's MS6-SV soft-start and quick exhaust valve for interrupting the
trained
compressed air supply as required.
Reading these Operating Instructions in their entirety
Following all instructions and safety rules in these Operating Instructions
Carrying out all the specified inspection and servicing work
Protection against solid foreign bodies larger than Ø 12.5 mm (0.49 in.)
Protection against dripping water falling vertically
Set up a compressed air supply using the pressure relief valve and compressed air
filter
Guarantee the compressed air quality in accordance with ISO 8573-1:2001, class 7 4
3, instrument air
Solid particle concentration  10 mg/m
-
Pressure concentration point vapor  + 3°C
-
Oil concentration  1 mg/m
-