Performance Data - ProMinent Hydro/ 4 Assembly And Operating Instructions Manual

Metering pump
Table of Contents

Advertisement

10.4

Performance data

HA4a at 50 Hz operation
Piston Ø
Pressure
Pump capacity in l/h at strokes / min (50 Hz) Qrtd min. - Q
max.
71
mm
bar
l/h
40
40
-
40
25
-
40
16
-
40
10
-
40
7
-
52
25
-
52
16
-
52
10
-
52
7
-
63
16
(200) -
212
63
10
(210) -
215
63
7
(210) -
216
80
10
(280) -
350
80
7
(270) -
352
94
7
(350) -
493
How should I read the above table?
103
136
188
l/h
l/h
l/h
-
(150) -
(200) -
154
211
-
(150) -
(200) -
160
219
-
-
(200) -
225
(100) -
(150) -
(200) -
125
166
228
(100) -
(150) -
(200) -
127
167
230
(200) -
(200) -
(370) -
204
271
372
(190) -
(200) -
(370) -
205
274
376
(180) -
(200) -
(370) -
207
276
379
(180) -
(200) -
-
209
277
(280) -
(390) -
-
306
401
(280) -
(380) -
-
311
407
(280) -
(370) -
-
312
408
(420) -
(580) -
(890) -
509
657
914
(420) -
(590) -
(890) -
513
683
947
(500) -
(820) -
(1,000) -
710
936
1,258
Assumption:
The identity code of your pump starts as follows: HA4AV 052 010 A
S1 ... .
From this you can deduce the following using the identity code / product
identification at the beginning of the operating instructions:
Piston diameter = 052 mm,
n
Maximum pressure "p max" = 010 bar,
n
Stroke rate = 103 strokes/min.
n
Then use these values to find the information in the table: "(180) - 207
l/h".
That means:
the minimum sensible dosing rate "Q min" = 207 l/h/10 = 20.7 l/h
n
Stroke
Suction
volume
lift
(theor.)
214
l/h
ml/stroke
max.
water
column
(220) -
25.1
3
242
(220) -
25.1
3
250
(220) -
25.1
3
254
(220) -
25.1
3
256
(220) -
25.1
3
261
-
42.4
3
-
42.4
3
-
42.4
3
-
42.4
3
-
62.3
3
-
62.3
3
-
62.3
3
(1,050) -
100.4
3
1,056
(1,050) -
100.4
3
1,080
(1,400) -
138.7
3
1,440
Technical data
Suction /
pressure
side con‐
nector
G-DN
G 1 A -
DN15
G 1 A -
DN15
G 1 A -
DN15
G 1 A -
DN15
G 1 A -
DN15
G 1 ½ A -
DN25
G 1 ½ A -
DN25
G 1 ½ A -
DN25
G 1 ½ A -
DN25
G 1 ½ A -
DN25
G 1 ½ A -
DN25
G 1 ½ A -
DN25
G 2 A -
DN 32
G 2 A -
DN 32
G 2 ½ A -
DN40
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ha4a

Table of Contents