Tab. 7: HA4a
Design
Simplex
Duplex
Duplex - double head
Triplex
Triplex
+ Exde motor with frequency converter
10.6

Wetted materials

Material ver‐
Dosing head
sion
S1
Steel
P1
PVDF
H1
Hastelloy C
V1
PVC
Y1
PP
T1
PTFE
10.7

Ambient conditions

10.7.1

Temperatures

Tab. 8: Temperature data
Specification
Storage temperature:
Ambient temperature (during operation):
Tab. 9: Feed chemical / fluid
Material
Stainless steel
Hastelloy
PVDF
PTFE + carbon
PVC
PP
Connector
Seals
1.4404
PTFE
PVDF
PTFE
Hastelloy C
PTFE
PVDF
PTFE
PVDF
PTFE
PVDF
PTFE
* DN15 / DN25: no spring
Material abbre‐
Max. temp.
viation
SST
-20 ° C
HCT
-20 ° C
PVT
-20 ° C
TTT
-20 ° C
PCT
0 ° C
PPT
0 ° C
* not with ATEX
Weight approx.
DN15/25 ball
DN32/40 plate
1.4404
1.4404
glass
ceramic
Hastelloy C
Hastelloy C
glass
ceramic
glass
ceramic
glass
ceramic
-25 ... +60 °C
-20 ... +40 °C
Max. temp.
Max. temperature, for 15 min
+90°C
+90°C
+65 °C
+50 °C
+45 °C
+50 °C
Technical data
96 kg
160 kg
220 kg
220 kg
260 kg
Spring *
Hastelloy C
Halar (coating)
Hastelloy C
Halar (coating)
Halar (coating)
Halar (coating)
Value
at max. 2 bar
+120 °C *
+120 °C *
+100 °C *
+50 °C
+60 °C
+50 °C