ProMinent  von Taine 0807 PP Operating Instructions Manual
ProMinent  von Taine 0807 PP Operating Instructions Manual

ProMinent von Taine 0807 PP Operating Instructions Manual

Hide thumbs Also See for ProMinent von Taine 0807 PP:

Advertisement

Quick Links

Operating instructions

Magnetically coupled centrifugal pump
ProMinent
Please read the manual instructions completely before bringing the machine into service!
Damage caused by an operator´s error will cancel the right to all warranty claims!
Part-No. 987045
ProMinent Dosiertechnik GmbH • 69123 Heidelberg • Germany
®
von Taine
®
von Taine
0807 PVDF
o
Type:
0807 PP
Serial-No.
Please enter type + serial number of the pump here !
Do not throw it away!
®
0807 PP and PVDF
von Taine
o 0807 PVDF
®
0807 PP
BA vT 003 08/03 GB

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ProMinent von Taine 0807 PP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ProMinent ProMinent von Taine 0807 PP

  • Page 1: Operating Instructions

    Please read the manual instructions completely before bringing the machine into service! Do not throw it away! Damage caused by an operator´s error will cancel the right to all warranty claims! Part-No. 987045 ProMinent Dosiertechnik GmbH • 69123 Heidelberg • Germany BA vT 003 08/03 GB...
  • Page 2 Imprint Imprint: Operating instructions Magnetically coupled centrifugal pump ® ® ProMinent von Taine 0807 PP and PVDF © ProMinent Dosiertechnik GmbH, 2003 ProMinent Dosiertechnik GmbH Im Schuhmachergewann 5-11 69123 Heidelberg Germany info@prominent.de www.prominent.de Specifications subject to change without notice !
  • Page 3: Table Of Contents

    Table of contents TABLE OF CONTENTS General information ................... 5 Authorized use of the pump..................5 Sound intensity level....................5 Safety........................5 Identification of safety instructions in the operating manual........5 Qualification and training of operating personnel............6 Hazards in the event of non-compliance with safety instructions ......6 Compliance with regulations pertaining of safety work ..........
  • Page 4 Table of contents Disassembly of the pump ..................12 Re-assembly of the pump..................13 Troubleshooting ....................15 Technical data....................16 10 Spare parts ....................... 17 10.1 Exploded view ......................17 ® 10.2 Bill of materials von Taine 0807 PP ...............18 ® 10.3 Bill of materials von Taine 0807 PVDF..............18 11 Appendix ......................
  • Page 5: General Information

    (see the ProMinent list of resistances) symbol • If you deliver crystallising fluids, make sure that the fluid does not crystallise within the pump.
  • Page 6: Qualification And Training Of Operating Personnel

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF be observed and kept legible. safety instructions issued by the plant operator are to be observed. 2.2 Qualification and training of 2.5 Safety instructions relevant for operating personnel operation The personnel responsible for operation,...
  • Page 7: Unauthorized Alterations And Production Of Spare Parts

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 3.2 Storage An eventual storage place must be absolutely dry. Make sure that the interior of the pump is protected from pollutants. The pump is magnetically coupled. Attention: Coming in contact with 3.3 Ambient conditions required...
  • Page 8: Materials

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 5.2 Hoses and tubes NOTE The cross-sections of the tubes must The materials used are listed on the correspond to the suction and delivery name plate or the delivery note! ports. All suction and delivery tubes to the pump housing should be free of tensile stress.
  • Page 9: Starting And Shutdown Procedures

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF WARNING Do not check the direction of rotation without having filled fluid in the pump! F The motor must be equipped with a motor protection switch. F The power supply must have been cut...
  • Page 10: Starting Procedure

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 6.2 Starting procedure 6.4 Shutdown procedure F Switch on the motor. F Switch off the motor. F Check the direction of rotation of the F Close all shut-off devices. F In case some fluid remains within the motor by switching it on and off in immediate succession.
  • Page 11 ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF WARNING Make sure there are no magnetisable metal particles in the working area if you assemble or disassemble the pump! When the complete head of the pump is assembled or disassembled, magnetic...
  • Page 12: Disassembly Of The Pump

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 7.3 Disassembly of the pump 1. Remove the 6 screws (901.1) in the pump 2. Take the suction flange (162) off the pump housing (101). housing (161). Pull the impeller with the impeller magnet (230 + 847.1) and the...
  • Page 13: Re-Assembly Of The Pump

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 7.4 Re-assembly of the pump 1. Install bearings (310.1 and 310.2) to 2. Make sure that the impeller with impeller impeller magnet (847.1) and impeller magnet (230+847.1) and bearings (230). (310.1+310.2) installed properly rotates around the center shaft.
  • Page 14 ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF WARNING Once the complete head of the pump has been assembled, the impeller (230) and the impeller magnet (847.1) should be able to slide axially on the center shaft (211)! • Any other repair than the replacement...
  • Page 15: Troubleshooting

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 8 Troubleshooting Malfunction Causes Corrective action Pump does not work when No voltage Test the voltage switched on Impurities in the pump Remove the impurities housing Magnetic clutch is Specific gravity and/or Reduce the delivery rate;...
  • Page 16: Technical Data

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 9 Technical data Order- No. 1023090 1023096 ® ® Pump type von Taine 0807 PP von Taine 0807 PVDF Hydraulic data Maximum flow 6600 l/h 6600 l/h Operating range 60 - 6600 l/h...
  • Page 17: Spare Parts

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 10 Spare parts 10.1 Exploded view Page...
  • Page 18: Bill Of Materials Von Taine ® 0807 Pp

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF ® 10.2 Bill of materials von Taine 0807 PP Serial-No: Pos. Qty. Order-No. Designation Material Qty. PUMA.00.0250.071 lantern 161+314.2 PUMA.05.0050.036 pump housing with thrust ring polypropylene PUMA.05.0050.100 suction flange polypropylene PUMA.05.0050.083...
  • Page 19: Appendix

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF Pos. Qty. Order-No. Designation Material Qty. PUMA.00.0090.030 hexagon socket screw M5x12 inox PUMA.00.0370.029 feather 5x25x5 Subject to technical alteration! 11 Appendix ® 11.1 Dimensional drawing of von Taine 0807 PP and PVDF...
  • Page 20: Characteristic Curves

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 11.2 Characteristic curves ® von Taine 0807 PP/PVDF Dichte / density NPSH 1000 2000 3000 4000 5000 6000 7000 Förderleistung / capacity [l/h] 1000 2000 3000 4000 5000 6000 7000 Förderleistung / capacity [l/h]...
  • Page 21: Motor Data Sheet

    Les données techniques correspondent au descriptif du fabricant des moteurs. Les données techniques de moteurs similaires chez d´autres fabricants varient très peu. Ces données sont d´ordre général. Nr. / No. ProMinent Dosiertechnik GmbH · 69123 Heidelberg · Germany Datum / Date 05.12.2003 Page...
  • Page 22: Ec Declaration Of Conformity

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 11.4 EC Declaration of Conformity Page 22...
  • Page 23 Notes:...
  • Page 24 Addresses and delivery by the manufacturer / Adresses et liste des fournisseurs fourniesa par le constructeuer / Para informase de las direcciones de los distribuitores, dirigirse al fabricante â ProMinent Dosiertechnik GmbH Im Schuhmachergewann 5-11 • 69123 Heidelberg Germany Tel.: +49 6221 842-0 Fax.

This manual is also suitable for:

Prominent von taine 0807 pvdf

Table of Contents