Performance Data Of The Sigma 1 - ProMinent Sigma 1 Supplementary Operating Instructions

Pumps with hygienic pump head
Table of Contents

Advertisement

Technical data
11.1.1

Performance data of the Sigma 1

S1BA with hygienic pump head at 50
Hz operation
Type
Minimum pump capacity at maximum back pressure
bar
10022
10
10044
10
07065
7
Type
Maximum stroke
rate
Strokes/min
10022
73
10044
143
07065
205
S1BA with hygienic pump head at 60
Hz operation
Type
Minimum pump capacity at maximum back pressure
bar
10022
10
10044
10
07065
7
Type
Maximum
stroke rate
Strokes/min
10022
88
10044
172
07042
88
28
Priming lift
Suction lift
mbar
mbar
200
500
200
500
200
500
psi
145
145
102
Priming lift
Suction lift
mbar
mbar
200
500
200
500
200
500
l/h
24
46
68
Max. permissible pri‐
ming pressure on the
suction side
l/h
gph
29
7.6
55
21.4
81.1
21.4
Max. permissible pri‐
ming pressure on the
suction side
ml/stroke
5.5
5.3
5.5
Connector size
1
DN
10
10
10
ml/stroke
4.7
4.5
8.7
Connector size
1
DN
10
10
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sigma 2S1baS2ba100221004407065

Table of Contents