Technical Data; Performance Data - ProMinent Hydro/4 HP4a Operating Instructions Manual

Metering pump
Table of Contents

Advertisement

13

Technical data

Only with "M - modified" design:
13.1

Performance data

HP4a with 50 Hz operation
Type
Minimum pump capacity at maximum back
pressure
bar
250130
25*
250190
25*
250250
25*
250350
25*
250400
25*
160210
16*
160300
16*
160400
16*
160550
16*
160625
16*
100330
10
100480
10
100635
10
100880
10
101000
10
70465
7
70670
7
70890
7
71230
7
71400
7
l/h
ml/stroke
130
31
190
31
250
31
350
31
400
31
210
50
300
50
400
50
550
50
625
50
330
78
480
78
635
78
880
78
1000
78
465
109
670
109
890
109
1230
109
1400
109
* Maximum back pressure for TTT, PPT and PCT material versions: 10
bar!
All figures refer to water at 20 °C.
Priming lift / priming pressure (dry) determined for empty suction line and
empty liquid end and as well as clean and moistened valves (the figures
are lower with valve springs).
WARNING!
Risk of personal injuries
Please observe the "Supplement for modified version" at
the end of the chapter!
It replaces and supplements the technical data!
Maximum
suction lift
stroke rate
Strokes/min
m water
column
71
3 m
103
3 m
136
3 m
188
3 m
214
3 m
71
3 m
103
3 m
136
3 m
188
3 m
214
3 m
71
3 m
103
3 m
136
3 m
188
3 m
214
3 m
71
3 m
103
3 m
136
3 m
188
3 m
214
3 m
Technical data
Permis‐
Connector size
sible pri‐
ming pres‐
sure,
suction
side
bar
G-DN
1 bar
G1 1/2-DN25
1 bar
G1 1/2-DN25
1 bar
G1 1/2-DN25
1 bar
G1 1/2-DN25
1 bar
G1 1/2-DN25
1 bar
G1 1/2-DN25
1 bar
G1 1/2-DN25
1 bar
G1 1/2-DN25
1 bar
G1 1/2-DN25
1 bar
G1 1/2-DN25
1 bar
G 2" – DN32
1 bar
G 2" – DN32
1 bar
G 2" – DN32
1 bar
G 2" – DN32
1 bar
G 2" – DN32
1 bar
G2 1/4-DN 40
1 bar
G2 1/4-DN 40
1 bar
G2 1/4-DN 40
1 bar
G2 1/4-DN 40
1 bar
G2 1/4-DN 40
75

Advertisement

Table of Contents
loading

Table of Contents