CLMD16 User's Manual
__
Input A
This signal is connected to the first input of the lookup table for this logic element. You may select
from the list of signals in Table 11 - Available Signal Table.
Input B
This signal is connected to the second input of the lookup table for this logic element. You may
select from the list of signals in Table 11 - Available Signal Table.
Input C
This signal is connected to the third input of the lookup table for this logic element. You may select
from the list of signals in Table 11 - Available Signal Table.
Lookup Table
The lookup table consists of eight rows, one for each possible combination of values for the three
input signals. Set the value in the Output row of the table to the desired output signal value
corresponding to the A, B, and C signal values for that row.
63