On Level(S); Analog Reference; State; Voltage/Resistance/Current - Maretron MPOWER CLMD16 User Manual

16channel dc load controller module
Hide thumbs Also See for MPOWER CLMD16:
Table of Contents

Advertisement

___________________________________________________________

On Level(s)

This field allows you to select the input signal level that causes the corresponding field in the
127501 Binary Status Report message to be set to ON. You may select from one of the following
values:
• LOW
When the digital input is set to active low the corresponding field in the 127501 Binary
Status Report message will be set to ON when the input signal level is less than the Low
Threshold.
• HIGH
When the digital input is set to active low the corresponding field in the 127501 Binary
Status Report message will be set to On when the input signal level is greater than the

High Threshold.

Analog Reference

This field allows you to select the reference voltage for the input. You may select from one of the
following values:
• 5 VDC – select this option if the input signal will be limited to voltages between 0 – 5 VDC.
This will allow higher resolution measurements over this limited voltage range.
• Supply – select this option if the input signal will have voltages ranging from 0 VDC to the
supply voltage. This will allow the signal to be measured over the entire voltage range at the
expense of lower resolution.

State

This read-only field reflects the current state of the corresponding binary input signal. This field will
take one of the following three values:
• LOW – the input signal voltage is between 0 V and the set Low Threshold
• FLOAT – the input signal voltage is between the set Low and the High Thresholds
• HIGH – the input signal voltage is between the High Threshold and the Supply Voltage

Voltage/Resistance/Current

This read-only field reflects the present measured voltage (for channels 1-8), resistance (for
channels 9-10), or current (channel 11).
High Threshold
This numeric field allows you to program a voltage, resistance, or current value such that when the
detected value on the input signal transitions from below this value to above this value, the state of
the signal shall change from FLOAT to HIGH.

High Hysteresis

This numeric field allows you to program a hysteresis voltage, resistance, or current value such that
when the detected value on the corresponding input signal transitions from above the High
Threshold minus this value, the state of the output signal shall change from HIGH to FLOAT.
52