4: Tank Capacity – This field is used to indicate the tank capacity. This field is programmable
through the NMEA command PGN. The CLMD16 ships from the factory with a default value
of 0xFFFFFFFF indicating "Data Not Available".
5: Reserved – This field is reserved by NMEA; therefore, the CLMD16 sets all bits to a logic
1.
The CLMD16 uses this PGN to transmit DC voltage and current information.
Field 1: Sequence ID – This field is transmitted with a value of 255.
2: Connection ID – This field identifies the output channel (breaker) whose status is being
reported in this message. The value of this field will be in the range of 0 (Breaker #1)
through 15 (Breaker #16) or 16 (Analog / Digital Input #1) through 23 (Analog / Digital Input
#8)
3: DC Voltage – This field indicates the DC voltage sensed on the load or analog/digital input
pin
4: DC Current – This field indicates the DC current sourced by the load (this field shall be set
to "Data Not Available" for analog/digital inputs
5: Reserved bits – The CLMD16 sets all bits in this field to a value of "1"
79
PGN 127751 – DC Voltage/Current