CLMD16 User's Manual
This device, along with all other certified NMEA devices, has two user-programmable installation
description fields. You may program these fields with information specific to the device, such as
date installed, the initials/name of the installer, the physical location of the device, etc. This
configuration option will allow you to program the values of these fields.
The CLMD16 has four LED indicators to show system status.
This LED is used to indicate the state of operation of the touch controls. It can be in one of the
following states:
• Dark: this indicates normal operation
• Flashing red: this indicates a failure requiring service
This LED indicates the state of the NMEA 2000 network connected to the connector labelled "J4 /
CAN-A". It can be in one of the following states:
• Flashing blue: this indicates normal operation
• Dark: this indicates no communication is taking place
• Steady Blue: this indicates a fault on the NMEA 2000 network
This LED indicates the state of the NMEA 2000 network connected to the connector labelled "J5 /
CAN-B". It can be in one of the following states
• Flashing blue: this indicates normal operation
• Dark: this indicates no communication is taking place
• Steady blue: this indicates a fault on the NMEA 2000 network
This Bicolor LED indicates the condition of the power being supplied to the CLMD16
• Steady green: this indicates normal operation
• Flashing green: this indicates that the unit's 125A total current limit has been exceeded
• Steady red: this indicates that the power and ground connections to the unit have been
connected with reverse polarity
69
Operating the CLMD16
LED Indicators
DIAG
CAN-A
CAN-B
POWER
__