Available Signals; Configuring The Clmd16 - Maretron MPOWER CLMD16 User Manual

16channel dc load controller module
Hide thumbs Also See for MPOWER CLMD16:
Table of Contents

Advertisement

CLMD16 User's Manual
There are many signals that are available to connect as inputs for the various logic elements in the
switching application. The Table 11 is a complete list of the available signals.
Signal Name
None Selected
Binary Event 1 through 12 Low
Binary Event 1 through 12 Float
Binary Event 1 through 12 High
Network Input 1 through 16
Logic Output 1 through 8
Latch Output 1 through 8
Toggle Output 1 through 8
Timer Output 1 through 8
Flash Output 1 through 8
Counter Active 1 through 8
Over Current Fault Ch 1 through 16
Ch 1 through 16 Tripped
Ch 1 through 16 Thermal Limit Hit
Discrete I/O 1 through 16
The CLMD16 will transmit data over the NMEA 2000 ® network as it is shipped from the factory;
however, it may require configuration, depending on the type of switches monitored and the number
of similar products on the NMEA 2000 ® network. There are several configurable items within the
CLMD16, which are detailed in the remainder of this section.
The CLMD16 is configured using Maretron N2KAnalyzer ® V3 software. The following subsections
describe the configurable parameters in the CLMD16.
31

Available Signals

Table 11 - Available Signal Table
This connects the specified input to a constant Logic '0' value
The signal on binary event 1 through 12 is in the Low voltage range
The signal on binary event 1 through 12 is in the Float voltage range
The signal on binary event for the numbered channel is in the High
voltage range
The state of the signal on Network Input for the numbered channel
The state of the output of Logic Element for the numbered channel
The state of the output of Latch Element for the numbered channel
The state of the output of Toggle Element for the numbered channel
The state of the output of Delay Timer Element for the numbered
channel
The state of the output of Flash Element for the numbered channel
The state of the output of Counter Element 1 through 8
An Over Current Fault has been detected on Channel 1 through 16
The circuit breaker for the numbered channel is tripped
The circuit breaker for the numbered channel has reached its
thermal limit
The discrete state I/O of the signal the numbered channel

Configuring the CLMD16

Description
__

Advertisement

Table of Contents
loading

Table of Contents