___________________________________________________________
Wiring J1 – J3 Connectors
The J1-J3 receptacles on the CLMD16 Unit were designed to accept Deutsch brand DTP, DT, and
DRC series plugs. Maretron supplies optional premade 2m harnesses for the J1 and J2 connections
and a 2m wiring kit for the J3 connection. Alternatively, the installer may choose to wire the plugs
directly.

Wiring a Harness Directly to J1-J3

If connecting harnessing directly to the J1-J3 receptacles, a Deutsch HDT- 48-00 crimp tool will be
needed and possibly the Deutsch DTT-12-01 crimp tool (for 10 AWG Wire connections) (see: Figure
4) A description of the Deutsch brand components that will be needed for connecting to the J1-J3
connections are outlined in Table 3.
HDT-48-00 Crimp Tool (20 AWG – 12 AWG)
DTT-12-01 Crimp Tool (10 AWG)
Figure 4 - Required Deutsch Wire Crimping Tools