Low Threshold

This numeric field allows you to program a voltage, resistance, or current value such that when the
detected value on the input signal transitions from below this value to above this value, the state of
the signal shall change from LOW to FLOAT.

Low Hysteresis

This numeric field allows you to program a hysteresis voltage, resistance, or current value such that
when the detected voltage on the corresponding input signal transitions from above the Low
Threshold plus this value, the state of the output signal shall change from FLOAT to LOW.

Tanks Tab

This Tanks Tab contains parameters for configuring tank measurement via the two resistive
channels and the current loop channel. See Figure 23 for Tanks Tab detail.
Figure 23 - Tanks Configuration Tab Dialog Box
53