CLMD16 User's Manual
Current
This read-only field shows the real-time current passing through the breaker.
Status
This group of indicators show real-time status of the breaker.
Tripped
When lit, this read-only field shows that the breaker is in the TRIP state.
Instant Trip
When lit, this read-only field indicates that the breaker has tripped due to the instant trip feature.
Short Time Trip
When lit, this read-only field indicates that the breaker has tripped due to the short time trip feature.
Long Time Trip
When lit, this read-only field indicates that the breaker has tripped due to the long time trip feature.
Thermal Protection
When lit, this read-only field indicates that the breaker has been turned off due to the thermal
protection feature.
Load Shed
When lit, this read-only field indicates that the breaker has been turned off due to the load shedding
feature.
Hardware Fault
When lit, this read-only field indicates that the breaker has been turned off due to a hardware fault
being detected.
Short To Ground
When lit, this read-only field indicates that the breaker has been turned off due to it being detected
shorted to ground.
Short To Battery
When lit, this read-only field indicates that the breaker has been turned off due to it being detected
shorted to the DC supply voltage.
Over Current
When lit, this read-only field indicates that the breaker has tripped due to an overload being
detected.