Environmental; Environmental Testing - Maretron MPOWER CLMD16 User Manual

16channel dc load controller module
Hide thumbs Also See for MPOWER CLMD16:
Table of Contents

Advertisement

___________________________________________________________
Parameter
IEC 60945 Classification
Degree of Protection
Operating Temperature
Storage Temperature
Electric Field
Ignition Protection
Parameter
High Temperature Soak
Low Temperature Soak
Temperature Cycling (Operating)
Temperature Shock (Storage)
External Surface Temperature Test
Simulated Solar Radiation
Ignition Protection
Humidity (Soak)
Humidity - Cyclic
Dust Ingress
Water Ingress
Mechanical Shock - Drop Test
Mechanical - Shock
Mechanical - Bump
Vibration (General)
Vibration (Random)
Vibration (Resonant Search)
Chemical Resistance
Salt Spray
Electrical (Operating Voltage)
Electrical (Over Voltage)
Electrical (Reverse Polarity)
Electrostatic Discharge (ESD)

Environmental

Environmental Testing

Standard
EN 60068-2-2:2007
EN 60068-2-1:2007
IEC 60068-2-14:2009
IEC 60068-2-14:2009
ISO 8846
EN 60068-2-5:2010
ISO 8846
EN 60068-2-78:2002
EN 60068-2-30:2005
IEC 60529:2001
DIN 40050-9:1993
IEC 60529:2001
EN 60068-2-32:1993
60068-2-27:2009
60068-2-29:1993
60068-2-6: 1996
EN 60068-2-64:1995
60068-2-6: 1996
EN 60068-2-74:2000
EN 60068-2-52: 1996
SAE J1455:2011 Sect 4.13.1
SAE J1455:2011 Sect 4.13.1
SAE J1455:2011 Sect 4.13.1
ISO 13766:2006
Value
Exposed
IP67
-30°C to 70°C
-40°C to 70°C
30V/m
Ignition Protected
Conditions
Duration 96hrs, T max = 70°C
96 hrs, T min = -30°C
T min = -30°C, T max = 70°C
T min = -40°C, T max =70°C
Paragraph 4
Procedure = B, 10 days @ 40°C
RH = 93% +/-3%, Exposure 10 days
RH (> 90%), 6 cycles of 24hrs
Method EN60529 Section 13 Result
IP6X
Method as DIN 40050-9 Result IPX7
1000mm free-fall, all faces of 3 axes
500m/s 2 , pulse duration 11ms
400m/s 2 6ms shock pulses, 3 axes
Sine shaped sweep 5 Hz to 500 Hz
Method 1
frequency range 10 Hz – 2 kHz @ 5G
Test method = B
Severity=4, Duration: 96 hours
Test for impaired function
Test for impaired function +24V, +36V
Test for impaired function -24V, -36V
+/- 8 kV (Direct), +/- 15 kV (Air)
74

Advertisement

Table of Contents
loading

Table of Contents