The Flash function has the following input signals:
• Input – the flashing function is enabled as long as this signal is asserted (ON)
The Flash function has the following output signals:
• Flash Output – while the input signal is asserted this signal will be enabled allowing for the
configurable parameters to take control of the Flash Output function.
The Flash function has the following configurable parameters:
• Flash Cycles – once the Input signal is detected, the Flash Output signal will cycle for
this number of cycles, or until the Input signal is removed, whichever occurs first.
• Flash On Period – during each flash cycle, the Flash Output signal will be On for this
amount of time
• Flash Off Period – during each flash cycle, the Flash Output signal will be Off for this
amount of time
The output signals from the flash elements are numbered 1 through 8
The CLMD16 provides eight set/reset latches, which, as an example, may be used for loads which
use a push on/push off function.
The Latch function has the following input signals:
• Set Input – This signal will cause the Latch Output signal to turn On
• Reset Input – This signal will cause the Latch Output signal to turn Off
The Latch function has the following output signals:
• Latch Output – On when Set Input is detected or On, and Off when the Reset Input is
detected or On
The Latch function has no configurable parameters.