Min Set Point

This parameter allows you to configure the minimum value that the counter can reach. This is also
the value to which the counter is set when the Reset input is asserted high

Max Set Point

This parameter allows you to configure the maximum value that the counter can reach.

Press Step Size

This parameter allows you to configure the step size by which to increment or decrement the
counter when the increment or decrement input is pressed.

Hold Step Size

This parameter allows you to configure in Active High or Active Low mode, the value by which to
increment or decrement the counter after the increment or decrement input signal has been
asserted high (On) for Hold Period time, and every Held Step Time thereafter. In the Rising Edge,
Falling Edge, or Change mode, this is the value by which to increment or decrement the counter on
each detected edge of the increment or decrement input signal.

Hold Step Time

This parameter allows you to configure, in Active High or Active Low mode, the time interval after
which the action performed by a "held" input signal repeats while it remains active.

Hold Period

This parameter allows you to configure, in Active High or Active Low mode, the time after which the
input signal is considered "held" if it remains active.

Active Threshold

This parameter allows you to configure the counter value above which the Counter Active
output of the counter will be asserted high (On).
45