Breaker Status Led Indicators; Override Switches; Maintenance - Maretron MPOWER CLMD16 User Manual

16channel dc load controller module
Hide thumbs Also See for MPOWER CLMD16:
Table of Contents

Advertisement

___________________________________________________________
Each breaker in the CLMD16 has a green LED indicator that is located on the correspondingly
numbered switch on the touch panel. This LED can be in one of the following states:
• Dark: the breaker is turned OFF
• Steady green: the breaker is turned ON
• Flashing green: the breaker has been commanded to turn ON, but is turned OFF due to
an overcurrent or short circuit condition
The CLMD16 includes a touch panel made up of capacitive touch switches to allow you to manually
control the state of the breakers in the CLMD16 in the event of loss of NMEA 2000 network
communication or for service purposes.
To enter override mode, press and hold the OVERRIDE switch until the green LED on the
OVERRIDE switch is lit (1-2 seconds). While the green LED on the OVERRIDE switch is lit, the
state of the CLMD16 breakers is controlled only by the individually numbered switches on the
control panel, and all network control inputs are ignored.
Each switch has an LED that will be dark when the corresponding breaker is turned OFF and will be
lit green when the corresponding breaker is turned ON. To toggle the state of a breaker, press and
hold the corresponding breaker control switch until the LED changes state (about
0.5 seconds).
To exit override mode, press and hold the OVERRIDE switch until the green LED on the
OVERRIDE switch is dark (about 1 second). The breakers will immediately revert to their
automatically controlled state.
Regular maintenance is important to ensure continued proper operation of the Maretron CLMD16.
Perform the following tasks periodically:
• Clean the unit with a soft cloth. Do not use chemical cleaners as they may remove paint
or markings or may corrode the CLMD16 enclosure or seals. Do not use any cleaners
containing acetone, as they will deteriorate the plastic enclosure.
• Ensure that the unit is mounted securely and cannot be moved relative to the mounting
surface. If the unit is loose, tighten the mounting screws.

Breaker Status LED Indicators

Override Switches

WARNING
The CLMD16 DC 16 Channel Load Module is operated under remote control.
Before servicing any load-device connected to the CLMD16, you must first
disconnect the wire between the CLMD16 load terminal and the load device.
Failure to do so can result in serious bodily harm.