HikRobot CA Series User Manual page 71

Area scan camera
Table of Contents

Advertisement

different color temperatures. Ideally, the proportion of R channel, G channel and B channel in the
white region is 1:1:1.
White Balance
Mode
Off
Once
Continuous
Steps:
1. Click Analog Control > Balance White Auto.
2. Select Off as Balance White Auto.
3. Select Balance Ratio Selector and Balance Ratio according to actual demands
Balance Ratio Selector and Balance Ratio will be invalid when selecting Once or Continuous as
Balance White Auto.
When selecting Continuous as Balance White Auto, you can set AWB (Automatic White Balance)
Color Temperature Mode, as shown below.
Steps:
1. Click Analog Control > Balance White Auto.
CA/CE-Series GigE Area Scan Camera·User Manual
Table 10-4 White Balance Status Description
Parameter
Analog Control >
Balance White
Auto
Analog Control >
Balance White
Auto
Analog Control >
Balance White
Auto
Figure 10-19 Set White Balance
Parameter Value
Off
Once
Continuous
61
Description
You need to set the R, G, B value
manually, between 1 and 4095.
1024 means ratio is 1.0
Automatic white balance once.
Adjust the white balance for a
certain amount of time then stop. It
implements an algorithm that finds
possible gray areas in the Bayer
data.
Continuous automatic white
balance. It implements an
algorithm that finds possible gray
areas in the Bayer data.

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CA Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Ce seriesGige

Table of Contents

Save PDF