Overlap Exposure under External Trigger Mode
Trigger_in 1
Sensor
exposure
The camera will ignore the external signal in the readout section under this mode.
CA/CE-Series GigE Area Scan Camera·User Manual
Figure 6-7 Internal Trigger Overlap Exposure
Trigger_in 2
Exposure 1
Frame 1
Readout
Figure 6-8 External Trigger Overlap Exposure
Trigger_in 3
Exposure 2
Frame 2
Readout