Download Print this page

Christie CP2306-RGBe Installation And Setup Manual page 8

Hide thumbs Also See for CP2306-RGBe:

Advertisement

C—No access zone. Horizontal clearance of the no access zone must be a minimum of 1.0 meters.
D—Vertical distance to hazard zone. The hazard zone must be no lower than 2.5 meters (US
installations) or 2.0 meters (global installations) above any surface upon which any persons are
permitted to stand.
E—Represents the top view of the projector.
F—Represents the side view of the projector.
Lens
1.2-1.72:1, 0.69" DLPCine zoom
1.33-2.1:1, 0.69" DLPCine zoom
1.62-2.7:1, 0.69" DLPCine zoom
2.09-3.9:1, 0.69" DLPCine zoom
For Installations in the United States
The following must be in place for laser-illuminated projector installations in the United States:
The projection room shall be clearly identified by the posting of laser warning and restricted access
signs, and by restricting entry through physical means. The projection room sign must display the
warning "No direct exposure to beam shall be permitted".
The Christie Laser Projection System Installation Checklist must be fully completed after the
installation and sent to lasercompliance@christiedigital.com. A copy can remain on-site. This checklist
can be found as a separate document in the accessory box with the manual.
Certain US states have additional laser regulatory requirements. Go to www.christiedigital.com for
additional regulatory requirements.
Learn about the labels that may be used on the product. Labels on your product may be yellow or black and
white.
Hazard warnings also apply to accessories once they are installed in a Christie product that is connected to
power.
Fire and Shock Hazard
To prevent fire or shock hazards, do not expose this product to rain or moisture.
Do not alter the power plug, overload the power outlet, or use it with extension cords.
Do not remove the product enclosure.
Only Christie qualified technicians are authorized to service the product.
CP2306-RGBe, CP2308-RGBe, CP2310-RGBe Installation and Setup Guide
020-103451-02 Rev. 1 (05-2021)
Copyright
2021 Christie Digital Systems USA, Inc. All rights reserved.
©
Hazard distance (m)
Part number
108-494108-XX
1.51
108-495109-XX
1.51
108-496100-XX
1.51
108-497101-XX
1.51
Safety precautions
8