Caution! If not avoided, the following could result in minor or moderate injury.
This procedure must be performed by Christie qualified technicians.
Typically, horizontal boresight does not require adjustment. It should only be adjusted if a large horizontal
angular offset to the screen is required.
When adjusting boresight, you must maintain the boresight distance from the lens to the prism plane set by
Christie. For example, when you move the top screw outward, turn the bottom two boresight screws to
maintain the overall distance.
Only adjust horizontal boresight 1/8 of a turn or less at one time to maintain optimal lens performance
(factory setup of absolute lens distance to the prism). It is critical that you count each turn of the cap screws
to ensure accurate adjustment.
Ensure that the boresight lockdown screws are adequately tightened. Not adequately tightening the boresight
screws can result in excessive onscreen image vibration. After adjusting boresight, evaluate the onscreen
image vibration and re-adjust if needed.
1. Remove the lens surround.
2. Display the DC2K Boresight test pattern.
3. Loosen the right boresight set screw (B).
Right boresight cap screw
A
Right boresight set screw
B
4. Turn the right boresight cap screw (A) 1/16 of a turn clockwise.
5. Adjust the left boresight cap screw (C) equally in the opposite direction.
6. If the quality of the projected image has not improved, turn the right boresight cap screw 1/16 of turn
counter-clockwise. Make sure the left adjuster is adjusted equally in the opposite direction.
7. Check the screen each time an adjustment is made. The right-side adjustments affect the top right
and bottom left points on the screen. Once both cross hairs are in focus, lock the set screw for right
boresight.
8. Repeat steps 5 to 7 for the left side.
9. Verify that each corner of the screen is equally in focus. If this is not the case, repeat vertical
boresight.
CP2306-RGBe, CP2308-RGBe, CP2310-RGBe Installation and Setup Guide
020-103451-02 Rev. 1 (05-2021)
Copyright
2021 Christie Digital Systems USA, Inc. All rights reserved.
©
Left boresight cap screw
C
Left boresight set screw
D
Adjusting the image
30