Upgrading NXP-PLV Firmware
3. Press the red Master IP/URL field to open a Keyboard and enter the NetLinx Master's IP Address
(obtained from the Diagnostics - Networking Address dialog of the NetLinx Studio application).
4. Click Done to accept the new value and return to the System Configuration page.
5. Do not alter the Master Port Number value, as this is the default value used by NetLinx.
6. Press the Back button to return to the Protected Setup page and press the on-screen Reboot button
to restart the device and save any changes.

Step 3: Verify and Upgrade the panel firmware via an IP

1. Click the OnLine Tree tab in the Workspace window to view the devices on the System. The default
System value is one.
2. Right-click the associated System number (from the Workspace window) and select Refresh
System to detect of all devices on the current system, establish a new connection to the Master, and
refresh the System list with devices on that system.
3. After the Communication Verification dialog window verifies active communication between the
PC and the Master, verify the panel appears in the OnLine Tree tab of the Workspace window
(FIG. 54). The default Modero panel value is 10001.
FIG. 54
NetLinx Workspace window (showing connected Modero panel)
The panel firmware is shown on the right of the listed panel.
4. If the firmware being used is not current, download the latest Kit file by first logging in to
www.amx.com and then navigate to Tech Center > Firmware Files and locate your device from
within the Modero section of the Web page.
The latest firmware kit file is now device-specific.
Only the proper firmware should be loaded onto this specific device type.
5. Click on the desired Kit file link. Verify that you have downloaded the Modero Kit file to a known
location after you've accepted the Licensing Agreement.
6. From within Studio, select Tools > Firmware Transfers > Send to NetLinx Device from the Main
menu to open the Send to NetLinx Device dialog (FIG. 55). Verify the panel's System and Device
109
Showing the NetLinx master
firmware version and
device number
Showing the current device
firmware version and
device number
Shows NetLinx Studio
version number
NXP-PLV Modero PosiTrack Pilot Camera Controller