Upgrading NXP-PLV Firmware
8. Click OK three times to close the open dialogs, save your settings, and return to the main NetLinx
Studio application.
9. Click the OnLine Tree tab in the Workspace window to view the devices on the Virtual System. The
default System value is one.
10. Right-click on the Empty Device Tree/System entry and select Refresh System to re-populate the
list.
The device will not appear below the virtual system number (in the Online Tree tab) until both the
system number used in step 7 for the Virtual NetLinx Master (VNM) is entered into the Master
Connection section of the System Settings page and the device is restarted.
If the device does not appear, refer to the Troubleshooting section on page 111 for
more information.

Step 3: Confirm and Upgrade the firmware via the USB port

Use the CC-USB Type-A to Mini-B 5-wire programming cable (FG10-5965) to provide communication
between the mini-USB Program port on the device and the PC. This method of communication is used to
transfer firmware Kit files and TPD4 touch panel files.
A mini-USB connection is only detected after it is installed onto an active device.
Rebooting a previously powered and connected device allows the PC to detect the
panel and assign an appropriate USB driver.
1. Verify that the direct USB connection (Type-A on the panel to mini-USB on the panel) is configured
properly, using the steps outlined in the previous two sections.
2. With the panel already configured for USB communication and the Virtual Master setup within
NetLinx Studio, it's now time to verify that the device is ready to receive files.
3. After the Communication Verification dialog window verifies active communication between the
Virtual Master and the panel, click the OnLine Tree tab in the Workspace window (FIG. 51) to
view the devices on the Virtual System. The default System value is one.
4. Right-click on the System entry (FIG. 51) and select Refresh System to re-populate the list.
Verify the panel appears in the OnLine Tree tab of the Workspace window.
The default Modero panel value is 10001.
FIG. 51
NetLinx Workspace window (showing the panel connection via a Virtual NetLinx Master)
105
Showing the Virtual Master
firmware version and
device number
Showing NetLinx Studio
version number
Showing the current firmware version
and device number
NXP-PLV Modero PosiTrack Pilot Camera Controller