Wiring The Nxa-Avb/Ethernet Connectors And Cables - AMX NXP-PLV Operation/Reference Manual

Modero positrack pilot camera controller
Hide thumbs Also See for NXP-PLV:
Table of Contents

Advertisement

NXP-PLV Accessories

Wiring the NXA-AVB/ETHERNET connectors and cables

The inputs and outputs on the breakout box are separated into front and rear connectors. The rear
connectors are used to input external signals. The front connectors are used to communicate signals
between the NXA-AVB/ETHERNET and a target NXP-PLV. FIG. 8 provides a layout of the wiring
connection both into and from the breakout box.
Audio In - Left Channel
Audio In - Right Channel
FIG. 8
NXA-AVB/ETHERNET Breakout Box connector wiring diagram
The rear-panel wiring connections are described below (from left to right):
7
(6-pin captive wire)
(6-pin captive wire)
Microphone Out
(4-pin captive wire)
Comp/Y (BNC)
C (BNC)
Ethernet
(RJ-45)
12 VDC power
supply
• AUDIO IN:
6-pin captive wire connector, divided into left and right audio channels. Each
channel is divided into GND, IN+, and IN- terminal cable connectors
(2 sets of 3 for each channel).
An example of this cable is to strip the ends of 2 RCA audio cables and insert
them into their respective locations on the Audio In port.
Either a balanced (+, -, and GND) or unbalanced (+ and GND) audio
signal can be connected to this input.
• MIC OUT:
4-pin captive wire connector, divided into GND, OUT-, and OUT+ terminal
connectors.
An example of this cable is to strip the terminal ends of a 3.5mm mini-jack and
insert them into their respective locations on the Mic Out port. This signal can
be fed as a Line Level In to either an amplifier or an AMX VOL card.
Either a balanced (+, -, and GND) or unbalanced (+ and GND) audio signal
can be connected to this output.
• Video In BNCs: Feeds either Composite/S-Video Luma or S-Video Chroma signals into the
NXA-AVB/ETHERNET. This feed is then redirected out to a NXP-PLV through
the front Audio/Video CAT5 port.
• ETHERNET:
RJ-45 connector routes data to the NXP-PLV through the front Ethernet port.
These connections use a standard CAT5 Ethernet cable to provide
communication between the target touch panel, breakout box, and NetLinx
Master.
• PWR:
2-pin captive wire connector that connects to a 12 VDC-compliant power
supply. This port can be used to provide power to a NXP-PLV by sending it
through the NXA-AVB/ETHERNET (rear power connector through to the front
power connector).
GND
F
In (-)
R
In (+)
O
N
GND
In (-)
T
In (+)
GND(-)
Out (-)
Out (+)
R
E
A
R
NXP-PLV Modero PosiTrack Pilot Camera Controller
Audio/Video
(CAT5)
Ethernet Out
(CAT5)
Power to
NXP-PLV

Advertisement