3)
INITIALIZING THE INCHING SENSOR
(1)
Start engine after parking the machine on flat floor and blocking wheels.
(2)
Release parking brake and keep neutral gear shift.
(3)
Adjust the inching sensor linkage so that the regular voltage is supplied to inching sensor when
operating the pedal.
Regular voltage ; Before pedal operation (1 0.1V), After pedal operation (3.5 0.1V).
(4)
Stop the engine and then just KEY ON. (Release parking brake, keep neutral gear)
(5)
Connect the AEB STARTER to the T/M controller.
(6)
Push AEB STARTER over 3 seconds.
(7)
If display shows " IP", Step on the pedal fully.
(8)
If display shows " IP", release "OK"
After the successful completion, it displays "OK".
(9)
(10)
In case of abnormal running, it may display "STOP" with the appropriate error code.
(11)
After troubleshooting, start the machine again to repeat above.
Above works are to be done with the parking brake released, so machine's wheels must be
blocked for safety.
4)
DISPLAY DURING INCHPEDAL CALIBRATION
Symbol
Push down the pedal slowly until endposition
IP
is reached and hold this position
Release the pedal slowly until endposition is
IP
reached
IP blinkt
A problem occurred, release the pedal
slowly until endposition is reached
OK
Finished inchpedal calibration successful
FN and Stop
Shift lever not in Neutral position
FS and Stop
Sensor supply voltage AU1 is out of the
specified range
FO and Stop
Outputspeed_not_zero
SL and Stop
Sensor voltage below specified range
SU and Stop
Sensor voltage below specified range
IL and Stop
Sensor position for released pedal out of
specified range
IU and Stop
Sensor position for released pedal out of
specified range
TO and Stop
Time-out calibration, pedal not moved after
calibration start
DL and Stop
Angle between pedal positions released and
pressed to small
DU and Stop
Angle between pedal positions released and
pressed to small
FI and Stop
Sensor signal 1 and 2 don't match together
Meaning
3-29
Remarks
If the expected endposition could not be
reached, release the pedal and try again
Calibrations is aborted
Calibrations is aborted
Calibrations is aborted
Calibrations is aborted
Calibrations is aborted
Calibrations is aborted
Calibrations is aborted
Calibrations is aborted
Calibrations is aborted
Calibrations is aborted
Calibrations is aborted