Parameter (Number)
Block Title
MOTOR SHAFT POWER
ACTUAL VALUES
(Continued)
(01.17)
INVERTER GWh COUNTER
(01.18)
INVERTER MWh COUNTER
(01.19)
INVERTER kWh COUNTER
(01.20)
U-PHASE CURRENT (01.21)
V-PHASE CURRENT (01.22)
W-PHASE CURRENT (01.23)
FLUX ACTUAL % (01.24)
SPEED CHANGE RATE
(01.29)
NOMINAL TORQUE SCALE
(01.30)
3AXD50000011888
Table 12-4 Level 1 Parameter Block Definitions
Selection (Value)
Default: Read Only
Range: -32768 to + 32767 kW or HP
Estimated mechanical power at motor shaft. The unit is selected by
parameter 96.16 Unit selection. A filter time constant for this signal
can be defined by parameter 46.14 Filter time power out.
Default: Read Only
Range: 0 - 65535 GWh
Energy in GWh - Amount of energy that has passed through the drive
(in either direction) in full gigawatt-hours. The minimum value is zero.
Default: Read Only
Range: 0 - 999 MWh
Energy in MWh - Amount of energy that has passed through the drive
(in either direction) in full megawatt-hours. Whenever the counter rolls
over, 01.18 Inverter GWh counter is incremented. The minimum value
is zero.
Default: Read Only
Range: 0 - 999 kWh
Energy in kWh - Amount of energy that has passed through the drive
(in either direction) in full kilowatt-hours. Whenever the counter rolls
over, 01.19 Inverter MWh counter is incremented. The minimum value
is zero.
Fieldbus Equivalent: 10 = 1kWh
Default: Read Only
Range: -30000.00 to +30000.00A
Measured U-phase current.
Default: Read Only
Range: -30000.00 to +30000.00A
Measured V-phase current.
Default: Read Only
Range: -30000.00 to +30000.00A
Measured W-phase current.
Default: Read Only
Range: -0 to +200%
Used flux reference in percent of nominal flux of motor.
Default: Read Only
Range: -15000 to +15000 RPM
Rate of actual speed change. Positive values indicate acceleration,
negative values indicate deceleration.
See also parameters 31.32 Emergency ramp supervision, 31.33
Emergency ramp supervision delay, 31.37 Ramp stop supervision and
31.38 Ramp stop supervision delay.
Default: Read Only
Range: 0.0000 - lb-ft
Nominal Torque - Torque that corresponds to 100% of nominal motor
torque.
The unit is selected by parameter 96.16 Unit selection.
Note: This value is copied from parameter 99.12 Motor nominal torque
if entered. Otherwise the value is calculated from other motor
data.