Table 13-1 Warning Messages (Alphabetical by Keypad Text)
Warning
Edge counter 2
(Editable message text)
Programmable warning:
33.45 Edge counter 2
warn message
Value counter 1
(Editable message text)
Programmable warning:
33.55 Value counter 1
warn message
Value counter 2
(Editable message text)
Programmable warning:
33.65 Value counter 2
warn message
Device clean
DC capacitor
Cabinet fan
Cooling fan
Additional cooling
AI supervision
Programmable warning:
12.03 AI supervision
function
Signal supervision
(Editable message text)
Programmable warning:
32.06 Supervision 1 action
32.16 Supervision 2 action
32.26 Supervision 3 action
External warning 1
(Editable message text)
Programmable warning:
31.01 External event 1 source
31.02 External event 1 type
External warning 2
(Editable message text)
Programmable warning:
31.03 External event 2 source
31.04 External event 2 type
External warning 3
(Editable message text)
Programmable warning:
31.05 External event 3 source
31.06 External event 3 type
External warning 4
(Editable message text)
Programmable warning:
31.07 External event 4 source
31.08 External event 4 type
External warning 5
(Editable message text)
Programmable warning:
31.09 External event 5 source
31.10 External event 5 type
FA2FA DDCS com
loss
Programmable warning:
60.79 INU-LSU com loss ctrl
13-8 Troubleshooting
Fault #
Cause
A889
Warning generated by
edge counter 2.
A88A
Warning generated by
value counter 1.
A88B
Warning generated by
value counter 2.
A88C
Warning generated by an
ontime timer.
A88D
Programmable warnings:
33.14 On-time 1
A88E
warn message
A88F
33.24 On-time 2
warn message
A890
A8A0
An analog signal is outside
the limits specified for the
analog input.
A8B0
Warning generated by
a signal supervision
function.
A981
Fault in external device 1.
A982
Fault in external device 2.
A983
Fault in external device 3.
A984
Fault in external device 4.
A985
Fault in external device 5.
AF80
DDCS (fiber optic)
communication between
converters (for example,
the inverter unit and the
supply unit) is lost.
What to do
Check the source of the warning (parameter 33.43 Edge
counter 2 source).
Check the source of the warning (parameter 33.53 Value
counter 1 source).
Check the source of the warning (parameter 33.63 Value
counter 2 source).
Check the event log for an auxiliary code.
Check the source of the warning corresponding to the
code:
0: 33.13 On-time 1 source
1: 33.23 On-time 2 source
10: 05.04 Fan on-time counter.
Check signal level at the analog input.
Check the wiring connected to the input.
Check the minimum and maximum limits of the input in
parameter group 12 Standard AI.
Check the source of the warning (parameter 32.07, 32.17
or 32.28).
Check the external device.
Check setting of parameter 31.01 External event 1
source.
Check the external device.
Check setting of parameter 31.03 External event 2
source.
Check the external device.
Check setting of parameter 31.05 External event 3
source.
Check the external device.
Check setting of parameter 31.07 External event 4
source.
Check the external device.
Check setting of parameter 31.09 External event 5
source.
Check status of other converter (parameters 06.36 and
06.39).
Check settings of parameter group 60 DDCS
communication. Check the corresponding settings in the
control program of the other converter.
Check cable connections. If necessary, replace cables.
3AXD50000011888