Parameter (Number)
Block Title
STANDARD DIO,
DIO DELAYED STATUS (11.02)
FI, FO
(Continued)
DIO1 FUNCTION (11.05)
DIO1 OUTPUT SOURCE (11.06) Default: Ready run (2)
RO/DIO control word bit 0 (40) Bit 0 of 10.99 RO/DIO control word
RO/DIO control word bit 1 (41) Bit 1 of 10.99 RO/DIO control word
RO/DIO control word bit 2 (42) Bit 2 of 10.99 RO/DIO control word
RO/DIO control word bit 8 (43) Bit 8 of 10.99 RO/DIO control word
RO/DIO control word bit 9 (44) Bit 9 of 10.99 RO/DIO control word
12-50 Startup Assistant & Parameters
Table 12-4 Level 1 Parameter Block Definitions
Selection (Value)
Output (0) DIO1 is used as a digital output
Input (1) DIO1 is used as a digital input
Frequency (2) DIO1 is used as a frequency input
Not energized (0) Output is off
Energized (1) Output is on
Ready run (2) Bit 1 of 06.11 Main status word
Enabled (4) Bit 0 of 06.16 Drive status word 1
Started (5) Bit 5 of 06.16 Drive status word 1
Magnetized (6) Bit 1 of 06.17 Drive status word 2
Running (7) Bit 6 of 06.16 Drive status word 1
Ready ref (8) Bit 2 of 06.11 Main status word
At setpoint (9) Bit 8 of 06.11 Main status word
Reverse (10) Bit 2 of 06.19 Speed control status word
Zero speed (11) Bit 0 of 06.19 Speed control status word
Above limit (12) Bit 10 of 06.17 Drive status word 2
Warning (13) Bit 7 of 06.11 Main status word
Fault (14) Bit 3 of 06.11 Main status word
Fault (-1) (15) Inverted bit 3 of 06.11 Main status word
Open brake command (22) Bit 0 of 44.01 Brake control status
Ext2 active (23) Bit 11 of 06.16 Drive status word 1
Remote control (24) Bit 9 of 06.11 Main status word
Supervision 1 (33) Bit 0 of 32.01 Supervision status
Supervision 2 (34) Bit 1 of 32.01 Supervision status
Supervision 3 (35) Bit 2 of 32.01 Supervision status
Other [bit] Source selection (see Terms and abbreviations)
Default: Read Only
Range: 0000b - 0011b
Displays the delayed status of digital input/outputs DIO2 and DIO1.
This word is updated only after activation/deactivation delays (if any
are specified). Example: 0010 = DIO2 is on, DIO1 is off.
This parameter is read-only.
Default: Output (0)
Range: 0 - 2
Selects whether DIO1 is used as a digital output or input, or a
frequency input.
Range: 0 - 44, Other
Selects a drive signal to be connected to digital input/output DIO1
when parameter 11.05 DIO1 function is set to Output.
Descriptions