Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway
B.2
BS3x0
Figure 66.
Cable
length
(metres)
Table 2 Power consumption (watts) of base stations and cabling when powered with 48 V
2007-06-18/ Ver. E
0.4 mm wire size (∅)
0 EPP
1 EPP
0
5.0
5.0
100
5.2
5.1
200
5.3
5.2
300
5.6
5.3
400
5.8
5.5
500
6.1
5.6
600
6.5
5.8
700
7.1
6.0
800
8.1
6.2
900
-
6.5
1000
-
6.9
1100
-
7.3
1200
-
8.1
1300
-
-
1400
-
-
1500
-
-
1600
-
-
1700
-
-
1800
-
-
1900
-
-
2000
-
-
2100
-
-
2200
-
-
2300
-
-
2400
-
-
2500
-
-
2600
-
-
2700
-
-
2800
-
-
2900
-
-
3000
-
-
3200
-
-
3400
-
-
3600
-
-
3800
-
-
4000
-
-
0.5 mm wire size (∅)
0.6 mm wire size (∅)
0 EPP
1 EPP
0 EPP
5.0
5.0
5.0
5.1
5.1
5.1
5.2
5.1
5.1
5.3
5.2
5.2
5.5
5.3
5.3
5.6
5.4
5.4
5.8
5.5
5.4
6.0
5.6
5.5
6.2
5.7
5.6
6.5
5.8
5.7
6.9
5.9
5.8
7.3
6.1
5.9
8.1
6.2
6.1
-
6.4
6.2
-
6.6
6.4
-
6.9
6.6
-
7.2
6.8
-
7.5
7.0
-
8.1
7.3
-
9.6
7.8
-
-
8.4
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TD 92372GB
1 EPP
5.0
5.1
5.1
5.1
5.2
5.2
5.3
5.3
5.4
5.4
5.5
5.6
5.6
5.7
5.8
5.8
5.9
6.0
6.1
6.2
6.3
-
6.4
-
6.5
-
6.6
-
6.8
-
6.9
-
7.1
-
7.3
-
7.6
-
7.9
-
8.4
-
-
-
-
-
-
-
-
-
-
70