Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway
5.2.2
RFP Cable
The RFP cable connects the IPBL with the RFPs. The maximum cable length between IPBL
and a single RFP must not exceed 1500 meters.
Note: Ensure that during the installation, each RFP is given an extra length (5-10 metres)
of cable because it is possible that it will have to be moved for one reason or another.
1
Cut the cable to the correct length.
2
Connect the cable to a RJ45 modular jack. For information on the pinning, see
figure
IMPORTANT: If local power supply is used for the RFP, the EPP cable pairs must not be
3
Label the cable.
Figure 29.
RJ45
modular jack
Figure 15. Connector pinning of the RFP cable.
5.2.3
LAN Cable
1
Cut the cable to the correct length.
2
Connect the cable to a RJ45 modular jack. For information on the pinning, see
figure
3
Label the cable.
Figure 30.
RJ45
modular jack
Figure 16. Connector pinning of the Ethernet cable.
2007-06-18/ Ver. E
15.
connected.
1
2
3
4
5
6
16.
1
2
3
4
5
6
7
8
EPP= Express Power pairs
SC = Data pair lead
NC= Not Connected
7
8
NC = Not Connected
TD 92372GB
22