Air Sync; Rfps - ASCOM IP-DECT Base Station Installation And Operation Manual

Hide thumbs Also See for IP-DECT Base Station:
Table of Contents

Advertisement

Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway
7.7.2

Air Sync

This section only applies to the IPBS.
Air Sync status is displayed in the Device Overview > Air Sync menu. For explanation on
the information shown for the active and the alternative sync bearers, see the table below.
Figure 52.
RFPI
Carrier
Slot
Hop
RSSI
FER
7.7.3

RFPs

This section only applies to the IPBL.
Information about the DECT devices connected to the IPBL. For explanation on the
information, see the table below.
1
Select Device Overview > RFPs.
Figure 53.
Figure 27. Connected RFPs to the IPBL
2
Click the applicable port to open the RFP details pop-up window.
2007-06-18/ Ver. E
Radio Fixed Part Identity is the Id number of the sync bearer.
The carrier used for air synchronization
The slot used for air synchronization
The number of hops from the sync master to the sync bearer
Received Signal Strength Indication
Frame Error Rate, a value between 0 and 100%. Should be
below 80% to be able to keep the synchronization.