Rfp Power Consumption - ASCOM IP-DECT Base Station Installation And Operation Manual

Hide thumbs Also See for IP-DECT Base Station:
Table of Contents

Advertisement

Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway
Appendix B: RFP Power Consumption
The tables below show power consumption for a base station connected to the IPBL. The
power consumption of the IPBL is approximately 15 W.
Note: The maximum cable length for base stations connected to the IPBL must not
exceed 1500 meters.
B.1
KRCNB 201/DCT1800
Figure 65.
Cable
length
(metres)
Table 1 Power consumption (watts) of base stations and cabling when powered with 48 V
2007-06-18/ Ver. E
0.4 mm wire size (∅)
0 EPP
1 EPP
0
7.5
7.5
100
7.9
7.8
200
8.3
8.0
300
8.9
8.3
400
9.8
8.7
500
11.3
9.2
600
-
9.8
700
-
10.7
800
-
12.3
900
-
-
1000
-
-
1100
-
-
1200
-
-
1300
-
-
1400
-
-
1500
-
-
1600
-
-
1700
-
-
1800
-
-
1900
-
-
2000
-
-
2100
-
-
2200
-
-
2300
-
-
2400
-
-
2500
-
-
2600
-
-
2700
-
-
0.5 mm wire size (∅)
0.6 mm wire size (∅)
0 EPP
1 EPP
0 EPP
7.5
7.5
7.5
7.8
7.7
7.7
8.0
7.8
7.8
8.3
8.0
8.0
8.7
8.2
8.2
9.2
8.5
8.4
9.8
8.7
8.6
10.7
9.0
8.8
12.3
9.4
9.1
-
9.8
9.5
-
10.3
9.9
-
11.1
10.4
-
12.3
11.1
-
-
12.1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TD 92372GB
1 EPP
7.5
7.6
7.7
7.8
7.9
8.0
8.2
8.3
8.4
8.6
8.8
8.9
9.1
9.3
-
9.6
-
9.9
-
10.2
-
10.6
-
11.1
-
11.7
-
12.7
-
-
-
-
-
-
-
-
-
-
-
-
-
-
69