Mortise Reinforcer And Mortise Lock Installation - Assa Abloy Corbin Russwin FE6600 Series Installation Instructions Manual

Multi-point lock
Hide thumbs Also See for Corbin Russwin FE6600 Series:
Table of Contents

Advertisement

FE6600 and BL6600 Series
Multi-Point Lock
Installation Instructions
5
Addendum (cont .)
m

Mortise Reinforcer and Mortise Lock Installation

• Remove the two (2) #12-24x1" flat head LBC mounting screws that are securing the lockbody case in
the door. (Figure 52)
• Place mortise reinforcer into the door.
• Reinstall two (2) #12-24x1" flat head LBC mounting screws
(DO NOT FORCE).
• Install two (2) #12x1/4" self tapping screws
through mortise reinforcer into the face of the door.
(Figure 53)
Note:
Reinforcer lip
belongs on the side
of the door that has
a special cutout at
the door edge.
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2017, 2019, 2020 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in
whole or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Figure 53
23
Figure 52
FM440 03/20