Multi-Point Lock
FM7300 Series and BL7300 Series
Installation Instructions
5
Addendum (cont.)
m

Mortise Reinforcer and Mortise Lock Installation

• Remove the two (2) #12-24x1" flat head LBC mounting screws that are securing the lockbody case in
the door. (Figure 52)
• Place mortise reinforcer into the door.
• Reinstall two (2) #12-24x1" flat head LBC mounting screws
(DO NOT FORCE).
• Install two (2) #12x1/4" self tapping screws
through mortise reinforcer into the face of the door.
(Figure 53)
Note:
Reinforcer lip
belongs on the side
of the door that has
a special cutout at
the door edge.
n

Final Installation

Refer to Section 3 "Installation" on page 6
1-800-727-5477 • www.sargentlock.com
Copyright © 2020 SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or in
part without the express written permission of SARGENT Manufacturing Company is prohibited.
Figure 53
23
Figure 52
A8220D 04/20