FE6600 and BL6600 Series
Multi-Point Lock
Installation Instructions
4
Optional Installation (cont .)
a
Dogging Indicator Installation (cont .)
1. Using a #7 drill bit, drill two (2) holes completely through door, making sure
drill remains square to face of door. (Figure 30)
2. Countersink holes on opposite face of door
to fit supplied oval head screws. (Figure 31)
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2017, 2019, 2020 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in
whole or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Figure 30
Figure 31
15